English
Language : 

PBJE45-10 Datasheet, PDF (1/4 Pages) Powerbox – 45-100 WATTS DC/DC SINGLE DUAL & TRIPLE OUTPUT
PBJE Series
45-100 WATTS DC/DC SINGLE DUAL & TRIPLE OUTPUT
Features
• Low cost
• Available in AC or DC input
• Fully isolated output
• AC power fail signal, optional
• Short circuit protection
• Overvoltage protection
Specifications
INPUT
Input voltage
115/230VAC dual selectable
9–18VDC, add “-12” to model No.
18–36VDC, add “-24” to model No.
36–72VDC, add “-48” to model No.
Input protection
Input fuse
Inrush current
AC inputs: 25A
OUTPUT
Output Voltage
See table
Output Voltage Adjustment Output 1 adjusts from -10% to OVP trip point
For AC inputs, 60W & 100W Output 2 adjusts
±10%
Output current
See table
Ripple & noise
1% typical, 2% max.
Line regulation
0.4% typical
Load regulation
Output 1, 1% typical; Outputs 2 & 3, 2-3% typical
Overvoltage protection Yes, on Output 1
Overload protection
Yes, at 125%–150% rated power
Short circuit protection Yes
Transient response
3mS for AC inputs, 50% load change
Holdup time
20mS min. after loss of AC input
Rise time
400mS typical for DC inputs
Remote sense
Available on AC input units, single outputs
OPERATING
Efficiency
70%–75% typical
Safety isolation
AC Input:Input – Output: 3750VAC
Input – Ground: 1500VAC
Output – Ground: 500VAC
DC Input: Input – Output: 1500VAC
Input – Ground: 500VAC
Output – Ground: 500VAC
Remote inhibit
Yes for AC input
Powerfail
Yes for AC input, optional
ENVIRONMENTAL
Operating temperature 0°C to 50°C full rating
Inside rack space
50°C to 70°C derate linearly to half load
Storage temperature
-20°C to 85°C
Cooling
Convection cooled
STANDARDS AND APPROVALS
Safety standards
IEC60950-1/UL60950-1 Class 1
C-Tick
AS/NZS CISPR11: 2002 Group1 Class A
EMI standards
Meet CISPR PUB 22, FFCC Class B
MECHANICAL
Dimensions
45W: 30.3x128.7x160mm
60W: 40.5x128.7x160mm
100W: 50.6x128.7x160mm
Connector
DIN 41612-15
Your dependable power partner – www.powerbox.com.au
407