English
Language : 

PBI3H Datasheet, PDF (1/2 Pages) Powerbox – 1 0 0 WAT T S D C / D C S W I T C H I N G P O W E R S U P P LY
PBI3H Series
1 0 0 WAT T S D C / D C S W I T C H I N G P O W E R S U P P LY
FEATURES
• Light weight, compact size
• Din Rail Mountable
• High efficiency, high reliability
• Input under voltage protection
• Over current, over voltage, thermal protection
• UL, cUL, CE
SPECIFICATIONS
INPUT
Input voltage
Inrush current
Efficiency (typical) *1
Switching Frequency
OUTPUT
Output voltage
Output Current
Voltage adjustment
Ripple & noise(max.) *2
Line regulation
Load regulation
Temperature coefficient *3
Drift *4
Dynamic Load Regulation *5
Recovery Time *5
Rise Time
12VDC (9.6-16)
24VDC (19~32)
48VDC (38~63)
110VDC (85~140)
12VDC (6.18A - 8.26A)
24VDC (3.3A - 5.4A)
48VDC (1.65A -2.64A)
110VDC (0.725A - 1.16A)
89% - 94%
125kHz fix
3.3Vdc - 24Vdc
22.0A - 5.0A
±10% of Rated Output Voltage
150mV - 350mV
26mV - 190mV
30mV - 216mV
0.03 % / °C
32mV - 135mV
±150mV - ±720mV
20mS
200mS(500mS for NVDxSD
Series)(maximum) at 25C and rated
input/output
NOTE:
*1 at DC 12, 24, 48, 110V and rated output
*2 measured by a bayonet probe at the output connector at a 0 to
100MHz bandwidth
*3 at -10 to +71C
*4 for 7hour period after 1hour warm-up at 25C and rated
input/output
*5 when output current changed between 25% and 75% of rated
output current rapidly at rated input
*6 Latch timer type (for 110V input models). Output turns to hiccup
mode when output drops after over-load )
OPERATING
Over current Protection *6 Current Limitting
Over voltage Protection
Input Voltage Protection
Thermal Protection
Latch Type (output shutdown)
Output shutdown when input voltage
remains under the input range for 3
seconds (typ.)
Output shutdown when input voltage
remains under the input range for 3
seconds (typ.)
ENVIRONMENTAL
Operating temperature
-10 to 71°C
Temperature derating
3.5%/C(50C to 71C)
Operating Humidity
20-80%/RH (non-condensing)
Storage temperature
-20 to +85°C
Humidity
Withstanding Voltage
20 to 90%/RH
Primary-Secondary AC2,000V at 10mA for
1minute/Primary-Frame Ground AC2,000V
at 10mA for 1minute/Secondary-Frame
Ground AC1,000V at 10mA for 1minute
Isolation Resistance
Primary-Secondary-Frame Ground 50M
ohm(minimum) by DC500V insulation tester
Vibration
Shock
5-10Hz:10mm double amplitude,10-
55Hz:19.6m/s2,20minutes' period for
30minutes each along X,Y,Z axes(non-
operating)
196m/s2
STANDARDS AND APPROVALS
Safety
UL60950,C-UL(CSA60950),CE
MECHANICAL
Dimension [mm]
65(W)x101(D)x34(H) mm(Not include output
terminal)
Weight
250g
Doc. No. PBC9 Rev.D 11-12-13
Powering Progress – www.powerbox.com.au
93