English
Language : 

MI-LC2Z-IY Datasheet, PDF (1/2 Pages) Powerbox – 50-300 WATTS MILITARY READY TO USE COMPONENET
MI COMPAC Series
50-300 WATTS MILITARY READY TO USE COMPONENT
Features
• Inputs 28Vdc and 270Vdc
• Outputs 1 to 3, 1 to 95Vdc
• EMI Compliance: MIL-STD-461C&D/E
• Transients & Spikes: MIL-STD-704A, 1275A/B
• Quality System MIL-1-45208
• Reverse polarity protected
• Low noise FM control
Specifications
INPUT
Nominal input
28Vdc
270Vdc
Input range
18 – 50Vdc
125V – 400Vdc
Input spike limit
MIL-STD-704A
MIL-STD-1275A/B
-600V to +600Vdc
-250V to +250Vdc
800Vdc max
-600V to +600Vdc
Input surge limit
100Vdc
500Vdc
Overvoltage shutdown
50Vdc
400Vdc
Inrush current
110%
Reverse polarity protection 10A
Recommended Fuse
OUTPUT
110% of input typical
2A FO3A type
28Vdc
270Vdc
Output power
250W
250W
Clamp voltage
60Vdc
420Vdc
Overload protection
20A
4A
Set point accuracy
0.5% V nom typical
Load/Line regulation
0.2-0.5% V nom typical
Output temperature drift 0.01%/°C
Output noise
1%pp V nom
Output voltage trimming 50%-110%
Remote sense compensation 0.5V
Current Limit
MECHANICAL
Dimensions
OPERATING
Isolation characteristics
Input – output
Input to case
Output to case
105% – 125%
MI-LC
MI-MC, MI-PC
MI-NC, MI-QC, MIRC
219x64x25mm
219x125x25mm
219x186x25mm
4,242Vrms
28Vdc input: 2,121Vrms
270Vdc input: 2,500Vrms
500Vrms
382
ENVIRONMENTAL
Storage temperature
+100°C
Operating temperature case +85°C
Shutdown temperature +95°C typical
STANDARDS AND APPROVALS
EMI/RFI characteristics (MIL-STD-461C, D &E)
INPUT POWER LEADS
Conduct emissions
CE01, CE03, CE07, CE101, CE102
MIL-STD-461C & D (1 Up)
CE101 MIL-STD-461E (2 Up & 3Up)
Conducted susceptibility
CS01, CS02, CS06, CS101, CS114, CS116
MIL-STD-461C & D (1 Up)
CS101, CS114, CS116 MIL-STD-461E (2 Up & 3Up)
Selection Table
Single output
Dual output
Triple output
MI-LC [a] [b] – [c] [d]
MI-MC [a] [b] – [c] [e]
MI-NC [a] [b] – [c] [f]
MI-PC [a] [b] [b] – [c] [d] [d]
MI-QC [a] [b] [b] – [c] [e] [d]
MI-RC [a] [b] [b] [b] – [c] [d] [d] [d]
50–100W
200W
300W
100–200W
250–300W
150–300W
# For conduction cooled models add – cc at end of model number
Please substitute selection character (e.g. [a]) with value designator in the
appropriate table below.
A=INPUT VOLTAGE
NOMINAL RANGE
B=OUTPUT
VOLTAGE
C=PRODUCT
GRADE
2=28Vdc
18-50V
Z = 2Vdc 2 = 15Vdc I = -40°C to +85°C
6=270Vdc 125-475V(1) Y = 3.3Vdc 3 = 24Vdc
O = 5Vdc L = 28Vdc
M = -55°C to +85°C
M = 10Vdc 4 = 48Vdc
D=OUTPUT
POWER/CURRENT
5V
<5V
1 = 12Vdc
E=OUTPUT
POW./CUR.
୑5V
<5V
F=OUTPUT
POW./CUR.
୑5V <5V
Y = 50W
10A
U = 200W
–
S = 300W –
X = 75W
15A
S= –
60A
P = – 90A
W= 100W
20A
V= –
30A
(1) These units rated at 75% load from 125-150Vin: 5Vout @ 100W; 2Vout and
3.3Vout @ 30A.