English
Language : 

MI-J2Z-IJ Datasheet, PDF (1/1 Pages) Powerbox – 10-50 WATTS MILITARY COTS DC/DC CONVERTER
MI-JOO Series
10-50 WATTS MILITARY COTS DC/DC CONVERTER
Features
• 28Vdc and 270Vdc Inputs per MIL-STD-704D/E/F
• 155Vdc inputs per MIL-STD-1399A
• MIL-STD-810 environments
• Up to 23 W/in3
• 80-90% Efficiency
• Remote sense and current limit
Specifications
INPUT
Input voltage
No load power
dissipation
OUTPUT
Set point accuracy
Load/Line regulation
Output temperature drift
Output noise
Output voltage trimming
See input voltage chart
Typ 1.35W
0.5% V nom typical
0.05% V nom typical
0.02%/°C
1%pp V nom
50% – 110%
Remote sense compensation 0.5 V
Current limit
105% – 125%
Short circuit current
105% – 130%
OPERATING
Isolation
Input to Output 3,000Vrms
Output to Baseplate 500Vrms
Input to Baseplate 1,500Vrms
Efficiency
80 – 90%
ENVIRONMENTAL
I Grade
M Grade
Storage temperature
-55°C to +125°C
Operating temperature
(baseplate)
-40°C to +100°C
Power cycling burn-in
12hrs 25 cycles
Temperature cycled with
power off
Test data supplied at these
temperature
48 hrs, 12 cycles
65°C to +100°C
-40°C to +80°C
-65°C to +125°C
-55°C to +100°C
96hrs 200 cycles
48hrs, 12 cycles -
-65°C to +100°C
-55°C to +80°C
For Technical Illustration refer to page 230 in Module Section
STANDARDS AND APPROVALS
Environment (MIL-STD-8100)
Altitude – Method 500.2 70,000 feet
Humidity – Method 507.2 86/240 (%/hours)
Acceleration – Method 513.3 9 g’s
Vibration – Method 514.3 20g’s
Shock – Method 516.3
40g’s
Reliability (MIL-HDBK-217F)
25°C Ground benign
3,619,000 hours
50°C Naval sheltered
2,208,000 hours
65°C Airborne inhabited
cargo
Environmental compliance
1,701,000 hours
MIL-STD-810
Derating
NAVMAT P-4855-1A
MECHANICAL
Weight
85 grams
Dimensions
59.7 x 61.0 x 12.7mm
Selection Table
MI-J[A][B]-[C][D]
A = INPUT VOLTAGE
B = OUTPUT VOLTAGE
VNOM RANGE TRANS.
2= 28V 18–50V (1) 60V Z=2V T = 6.5V 2 = 15V K = 40V
5= 155V 100–210V 230V Y= 3.3V R = 7.5V N = 18.5V J = 48V
6= 270V 125–400V (2) 475V 0= 5V M = 10V 3 = 24V
7= 165V 100–310V
X= 5.2V 1 = 12V L = 28V
V= 5.8V P = 13.8V J = 36V
C = PRODUCT GRADE
D = OUTPUT POWER/CURRENT
у5V
<5V
I= -40°C to +100°C
A= 10W
M=-55°C to +100°C
Z=25W 5A
Y=50W 10A
Note :(1) 16V operation at 75% load (2) These units rated at 75% load from
125-150Vin: MI-26Z-XV, MI-26Y-XV, MI-260-XW.
Your dependable power partner – www.powerbox.com.au