English
Language : 

FARM-AC Datasheet, PDF (1/1 Pages) Powerbox – Autoranging 115/230VAC input
FARM AC/DC Front End
500-1000 WATTS - FILTER/AUTORANGING RECTIFIER MODULE
FEATURES
• Autoranging 115/230VAC input
• EMI filtering
• 500W to 100W models
• Inrush current limiting
• 96% Efficiency
• Mini sized package
• Power fail signal
• Module enable
• Safety agency approvals
• RoHS option
PRODUCTION INFORMATION
The FARM (Filter/Autoranging Rectifier Module) is an AC front which provides EMI filtering, autoranging line rectification, transient protection and
inrush current limiting. The FARM is available in either 500/750W or 750/1000W models in a mini sized package measuring only 57.9x55.9x12.7mm.
The FARM interfaces directly with worldwide AC mains and may be used with Vicor 300 V input DC/DC converters to realize an autoranging, high
density, low profile switching power supply. The FARM includes a microcontroller that continuously monitors the AC line to control bridge / doubler
operation. The user need only provide external capacitance to satisfy system hold-up requirements.
SPECIFICATIONS
GENERAL
Input voltage
Parameter
Output power rating
Efficiency
90-132/180-264VAC
FARM1
500W
750W
96% typical
FARM2
750W:(90-132Vac)
1000W:(180-264Vac)
STANDARDS
Safety
EMC Immunity
MECHANICAL
Dimensions
UL60950, EN60950, CSA60950
EN61000-4-5, EN61000-4-11, EN61000-3-3
579 x 36.8 x 12.7mm
TYPICAL APPLICATION
PART NUMBERING
274