DLM 600 Series
6 0 0 WAT T S P R O G R A M M A B L E D C S U P P LY
Features
• High power density
• High efficiency
• Remote voltage sense & remote operation
• Master/slave paralleling, active current sharing
• Low output noise
• CE mark, UL listing mark and C-UL listing mark
• Ethernet/LAN Interface Option
Specifications
INPUT
Input voltage
Frequency
90-132 / 180-264VAC,auto-ranging, 2 Wires +
ground
47-63Hz
Current
11A max. at 115VAC, 6A max. at 230VAC
OUTPUT
Voltage adjustment
Zero to rated output
Current adjustment
Zero to rated output
Ripple & Noise
Line regulation
Load regulation
Transient response
Stability
Temperature coefficient
ENVIRONMENTAL
See table
Voltage: 0.005% of Vmax + 2mV
Current: 0.01% of Imax + 2mA
Voltage: 0.005% of Vmax + 2mV
Current: 0.02% of Imax + 5mA
500␮s to steady-state output voltage
(within 0.1% of Vmax) for 50-100% or 100-50%
load change
+/-0.05% of maximum voltage or current over 8
hours after 30 minute warm-up time at fixed line,
load and temperature
0.02%/°C of maximum output voltage
0.03%/°C of maximum output current
Operating temperature 0°C to 50°
Storage temperature
Cooling
-40°C to 65°C
Internal variable speed fan with over-temperature
protection.
OPERATING
Efficiency
Parallel/Series operation
Remote sense
Remote programming
Remote monitoring
Displays and indicators
Software
Regulatory compliance
MECHANICAL
Case
Dimensions
Weight
Connectors
84% typical at maximum power
82% typical for DLM 5-7 and DLM 8-75
Up to 4 unit of the same model can be connected
in parallel, with active current sharing control.
Series operation, multiple units of same model can
be connected in series, limited by 300Vpk between
either output terminal and chassis
The maximum allowed load line drop with remote
sensing is 1V total for DLM 5-75 & DLM 8-75
model, 2V total for all other model
Voltage , current (0-100%) and OVP (5-110%) of
full scale can be programmed by selectable
0-5VDC, 0-10VDC, or 0-5KΩ
Voltage or current can be Monitored with user-
selectable ranges, scaled to 0-5VDC or 0-10VDC
Two 3.5 digital LED displays indicate voltage,
current and, over-voltage output set point, fault,
external off, remote and output on
LabVIEW® driver for M9G/M85
(Contact Powerbox)
CE mark, UL listing mark and
C-UL listing mark
Enclosed
1RU 44(H) x 216 (W) x 432mm(D)
4.4Kg
Input: IEC320
Output: Bus bar with 10-32 screws for 5-60VDC
models; terminal blocks with 6-32 screws for
80-300V models
Your dependable power partner – www.powerbox.com.au