English
Language : 

DCS8-140E Datasheet, PDF (1/4 Pages) Powerbox – 1000-3000 WATTS PROGRAMMABLE DC SUPPLY
DCS Series
1000-3000 WATTS PROGRAMMABLE DC SUPPLY
Features
• High power density
• Remote voltage sense & remote programming
• Wide range of output voltages
• High programming resolution with ethernet
interface
• Remote control
Specifications
INPUT
Input voltage
1KW: 200-250VAC, single phase; 100-132VAC
single phase, internal jumper selectable (see M1
option) 1.2KW: 200-250VAC, single phase; 100-
132VAC single phase, internal jumper selectable
(see M1 option) 3KW: 190-250VAC, three phase;
200-250VAC, single phase (Note: Max.power
output of 3KW supplies must be limited to 2.5KW
for single phase input)
Frequency
47-63Hz for both single and three phase input
Current
Soft start
ENVIRONMENTAL
1KW: 15A typ at 115VAC, 8A typ at 230VAC,
1.2KW: 18A typ at 115VAC, 9A typ at 230VAC,
3KW: 20A typ at 230VAC single phase, 14A typ at
230VAC three phase
Line current is lower than full load peak value
during turn-on or power application after restart
Operating temperature 0°C to 50° (No De-rating)
Storage temperature
-40°C to 85°C
Humidity range
0-80% RH, non condensing
Cooling
Internal fan with over-temperature protection
OUTPUT
Voltage adjustment
Zero to rated output
Current adjustment
Zero to rated output
Ripple & Noise
See table
Regulation (Line or Load) Voltage: 0.1% Current: 0.1%
Transient response
Typically recovers in < 1ms to 1% of steady-state
output voltage (within 1% of Vmax) for 70-100%
or 100-70% load change. 500␮s typical
Stability
Temperature Coefficient
+/-0.05% of maximum voltage or current over 8
hours after 30 minute warm-up time at fixed line,
load and temperature
0.02%/°C of maximum output voltage 0.03%/°C of
maximum output current
OPERATING
Efficiency
Remote sense
Remote programming
Overvoltage protection
Remote analog
programming
Software
Regulatory compliance
See table
The maximum allowed sense line drop is 4V per line
(2V on the DCS 8 and 10V 1KW and 1.2KW models
and 1V/ line for all 3KW models)
External jumper via rear panel connectors J3.
Crowbar type adjustable from 5-110% Protection
rated output using front panel control (local or
remote program selectable via J3 jumper)
Linearity: +/-1%
Accuracy: +/-5%
LabVIEW® driver for M9C/M85 (Contact Powerbox)
CE Mark on all models, FCC Part 15 Class A UL1012
and CSA 22.2 #220 (1 and 1.2 KW only)
Options and Accessories
INPUT VOLTAGE OPTIONS
M1
Factory configured for 115VAC input (1 and 1.2kW only)
REMOTE INTERFACE OPTIONS
M9C
Internal IEEE-488/RS 232 interface
M13
Locking shafts (front panel potentiometers)
M32
Master/slave cable configured for two or more units
M33
M51A
M85
M102
M130
Replace input connector with terminal block (3kW only)
Isolated analog programming control of
V/I/OVP and isolated V/I monitor outputs up to
500V relative to the supply’s return line
Multichannel slave interface
Front panel binding posts for 1kw or 1.2
kW, Models р30A, р100V. Not compatible with
M9C, M85, M130, M131, M133, M135, M136
LXI compliant 10/100 Base T Ethernet
remote control master interface; includes web
server for direct control of power supply via web
browser (MS Internet Explorer 6.0 or later)
M131
16-bit slave interface option for use with a
M130 master (3 ft. control cable included)
M133
Output disconnect and polarity reversal
controlled via SCPI commands. Limited to 1k or
1.2 kW, р 300V, р 60A
M135
M130 & M133 combination
M136
M131 & M133 combination
105-330-26 Rack slide kit (3kW)
484