Parameters
Sym bols
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
Iout
Iout
Iin
F
Vo p e n
Conditions
S pe c ific a tion
Vin (V) Vrmt (V) Tu (°C) Min. Typ. Max.
12±0.12 5±0.25 -10 ~ +55 6.5 7.0 7.5
12±1.2 5±0.25 -10 ~ +55 6.0 7.0 8.0
12±1.2 5±0.25 -10 ~ +55 -
0.7 1.2
12±1.2 5±0.25 -10 ~ +55 45
50
55
11,4
5±0.25 -10 ~ +55 1.200 1.300
-
Unit
m Arm s
m Arm s
Adc
kHz
Vrm s
Note
Note 1 :
Note 2:
Note 3:
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked
on mechanical drawing and any conductors.
Remote ON/OFF (CN1-5) has priority and can not be used in combination with External PWM Dimming
(CN1-3). When 'Ext.PWM' (CN1-3) is used 'Vrmt' (CN1-5) should not be connected.
The external PWM frequency should be in a range of 100 ~ 500 Hz. For other frequency please request.
The optimum is 250 Hz. Here you will normally not get a interference to the vertical sync. frequency.
TEST CIRCUIT :
Vin
12 V
Iin
A
V
F
F
CN1-1
CN1-2
Ext. PWM*
0/5V
CN1-3
T1
NC
CN1-4
Vrmt
2.5 Vdc ~ Vin
V
a
b SW1
CN1-5
1000:1
PROBE
Vopen
V
~
CN2-3
SW3
SW4
CN2-2
RL2 RL1
CN2-1
CL2
CL1
A
A
Iout
2
~
~
Iout1
SW5
SW 1
a
b
Operation of unit
O p e ra ti o n
Non operation
*) Only active when Vrmt is 0 Vdc or floating
EXTERNAL PWM-DIMMING ( Remote ON / OFF Detailed Circuit Diagram ):
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
Info@Power-Systems.de
All specifications are subject to change without notice.
Page (2)
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. : + 49 / 70 62 / 67 59 - 6
Fax: + 49 / 70 62 / 67 59 - 800
Version 1.0, 1st June 2007