English
Language : 

PS-M06D05S6-NJ4L Datasheet, PDF (2/2 Pages) Power Systems GmbH+Co.KG – DC-AC INVERTER UNIT 6,5 W DUAL OUTPUTS
DC-AC INVERTER UNIT
PS-M06D05S6-NJ4L(S) (6,5 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
ELECTRICAL CHARACTERISTICS :
Parameters
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
Sym bols
Iout
Iout
Iin
F
Vopen
Conditions
Vin (V)
Vrmt
(V)
Tu (°C)
5±0.05 5±0.25 0 ~ +60
5±0.5 5±0.25 0 ~ +60
5±0.5 5±0.25 0 ~ +60
5±0.5 5±0.25 0 ~ +60
4.75 5±0.25 0 ~ +60
Specification
Min. Typ. Max.
6.0
6.5
7.0
5.5
6.5
7.5
-
1.6
2.5
50
60
70
1.450 1.500
-
Unit
m Arm s
m Arm s
Adc
kHz
Vrm s
Note
Note 1 :
Note 2:
Note 3:
Note 4:
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked
on mechanical drawing and any conductors.
Remote ON/OFF (CN1-5) has priority and can not be used in combination with External PWM Dimming
(CN1-3). When 'Ext.PWM' (CN1-3) is used 'Vrmt' (CN1-5) should not be connected.
The external PWM frequency should be in a range of 100 ~ 500 Hz. For other frequency please request.
The optimum is normally at 250 Hz, and minimizes the interference disturbances of the vertical sync.
frequency.
Please contact us for 24V input voltage.
TEST CIRCUIT :
Vin
A Iin
5V
V
F
F
CN1-1
CN1-2
Ext. PWM*
0~5V
CN1-3
T1
NC
CN1-4
Vrmt
2.5 Vdc ~ Vin
V
a
b SW1
CN1-5
1000:1
PROBE
Vopen
V
~
CN2-1
SW3
SW4
CN2-2
RL2 RL1
CN2-4
CL2
CL1
A
A
Iout
2
~
~
Iout1
SW5
SW 1
a
b
Operation of unit
O p e ra ti o n
Non operation
*) Only active when Vrmt is 0 Vdc or floating
EXTERNAL PWM-DIMMING ( Remote ON / OFF Detailed Circuit Diagram ):
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
Info@Power-Systems.de
All specifications are subject to change without notice.
Page (2)
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. : + 49 / 70 62 / 67 59 - 6
Fax: + 49 / 70 62 / 67 59 - 800
Version 1.0.5, 12th February 2010