English
Language : 

PS-M05D12S3-NJ4L-012 Datasheet, PDF (2/2 Pages) Power Systems GmbH+Co.KG – DC-AC INVERTER UNIT 6,5 W DUAL OUTPUTS
DC-AC INVERTER UNIT
PS-M05D12S3-NJ4L-012(S) (6,5 W DUAL OUTPUTS)
ELECTRICAL CHARACTERISTICS :
(PRELIMINARY INFORMATION)
Parameters
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
Conditions
S ym bols
Vin (V)
Vrmt
Tu (°C)
(V)
Iout 12±0.12 5±0.25 0 ~ +60
Iout 12±1.2 5±0.25 0 ~ +60
Iin 12±1.2 5±0.25 0 ~ +60
F
12±1.2 5±0.25 0 ~ +60
Vopen 11,4 5±0.25 0 ~ +60
Specification
Min. Typ. Max.
4.5
5.0
5.5
4.0
5.0
6.0
-
0.7
1.2
45
55
65
1.100
-
-
Unit
m Arm s
m Arm s
Adc
kHz
Vrm s
Note
Duty 100%
Note 1 :
Note 2:
Note 3:
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked
on mechanical drawing and any conductors.
Remote ON/OFF (CN1-5) has priority and can not be used in combination with External PWM Dimming
(CN1-3). When 'Ext.PWM' (CN1-3) is used 'Vrmt' (CN1-5) should not be connected.
The external PWM frequency should be in a range of 100 ~ 500 Hz. For other frequency please request.
The optimum is normally at 250 Hz, and minimizes the interference disturbances of the vertical sync.
frequency.
TEST CIRCUIT :
Vin
12 V
A Iin
V
F
F
CN1-1
CN1-2
Ext. PWM*
0~5V
CN1-3
T1
NC
CN1-4
Vrmt
2.5 Vdc ~ Vin
V
a
b SW1
CN1-5
1000:1
PROBE
Vopen
V
~
CN2-1
SW3
SW4
CN2-2
RL2 RL1
CN2-4
CL2
CL1
A
A
Iout
2
~
~
Iout1
SW5
SW 1
a
b
Operation of unit
Operation
Non operation
*) Only active when Vrmt is 0 Vdc or floating
EXTERNAL PWM-DIMMING ( Remote ON / OFF Detailed Circuit Diagram ):
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
Info@Power-Systems.de
All specifications are subject to change without notice.
Page (2)
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. : + 49 / 70 62 / 67 59 - 6
Fax: + 49 / 70 62 / 67 59 - 800