DC-AC INVERTER UNIT
PS-M05D05S3-NJ4L-011(S) (6,5 W DUAL OUTPUTS)
ELECTRICAL CHARACTERISTICS :
(PRELIMINARY INFORMATION)
Parameters
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
S ym bols
Iout
Iout
Iin
F
Vopen
Conditions
Vrmt
Vin (V) (V) Tu (°C)
5±0.05 5±0.25 0 ~ +60
5±0.5 5±0.25 0 ~ +60
5±0.5 5±0.25 0 ~ +60
5±0.5 5±0.25 0 ~ +60
4.75 5±0.25 0 ~ +60
Specification
Min. Typ. Max.
4.5
5.0
5.5
4.0
5.0
6.0
-
1.6
2.5
50
60
70
900 950
-
Unit
m Arm s
m Arm s
Adc
kHz
Vrm s
Note
Duty 100%
Note 1 :
Note 2:
Note 3:
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked
on mechanical drawing and any conductors.
Remote ON/OFF (CN1-5) has priority and can not be used in combination with External PWM Dimming
(CN1-3). When 'Ext.PWM' (CN1-3) is used 'Vrmt' (CN1-5) should not be connected.
The external PWM frequency should be in a range of 100 ~ 500 Hz. For other frequency please request.
The optimum is normally at 250 Hz, and minimizes the interference disturbances of the vertical sync.
frequency.
TEST CIRCUIT :
Iin
Vin
A
5V
V
F
F
CN1-1
CN1-2
Ext. PWM*
0~5V
CN1-3
T1
NC
CN1-4
Vrmt
2.5 Vdc ~ Vin
V
a
b SW1
CN1-5
1000:1
PROBE
Vopen
V
~
CN2-1
SW3
SW4
CN2-2
RL2 RL1
CN2-4
CL2
CL1
A
A
Iout
2
~
~
Iout1
SW5
SW 1
a
b
Operation of unit
Op e ra tio n
Non operation
*) Only active when Vrmt is 0 Vdc or floating
EXTERNAL PWM-DIMMING ( Remote ON / OFF Detailed Circuit Diagram ):
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
Info@Power-Systems.de
All specifications are subject to change without notice.
Page (2)
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. : + 49 / 70 62 / 67 59 - 6
Fax: + 49 / 70 62 / 67 59 - 800