PS-M04D12S3-NJ1L-142 Datasheet, PDF (2/2 Pages) Power Systems GmbH+Co.KG – DC-AC INVERTER UNIT 6,5 W DUAL OUTPUTS
DC-AC INVERTER UNIT
PS-M04D12S3-NJ1L-142(S) (6,5 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
ELECTRICAL CHARACTERISTICS :
Parameters
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
S ym bols
Iout1+2
Iout1+2
Iin
F
Vopen
Conditions
Vin (V)
Vrmt
(V)
Tu (°C)
12±0.5 5±0.25 0 ~ +60
12±1 5±0.25 0 ~ +60
12±1 5±0.25 0 ~ +60
12±1 5±0.25 0 ~ +60
12±1 5±0.25 0 ~ +60
Specification
Min. Typ. Max.
3.5
4.0
4.5
3.0
4.0
5.0
-
1.6
2.5
50
60
70
1.250
-
-
Unit
m Arm s
m Arm s
Adc
kHz
Vrm s
Note
Note 1 :
Note 2:
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked
on mechanical drawing and any conductors.
You can use external PWM or Remote ON / OFF. Not both together.
In case of both together Remote ON / OFF has priority and ext. PWM is out of function.
If using ext. PWM let CN1-5 open.
TEST CIRCUIT :
Vin
12 V
A Iin
V
F
F
CN1-1
CN1-2
Ext. PWM*
0~5V
CN1-3
T1
NC
CN1-4
Vrmt
2.5 Vdc ~ Vin
V
a
b SW1
CN1-5
*) Only active when Vrmt is 0 Vdc or floating
1000:1
PROBE
CN2-1
SW3
Vopen
V
~
RL1
CL1
CN2-2 SW4
A
~ Iout1
SW5
CN3-1
RL2
CL2
CN3-2
SW6
A
~ Iout2
SW 1
a
b
Operation of unit
Op e ra tio n
Non operation
External PWM-Dimming / Remote ON / OFF Detailed Circuit Diagram :
Power Systems – The Power Solution
Web:
www.Power-Systems.de
Email:
Info@Power-Systems.de
All specifications are subject to change without notice.
Page (2)
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany