English
Language : 

PS-DA0605-02 Datasheet, PDF (2/5 Pages) Power Systems GmbH+Co.KG – DC-AC INVERTER UNIT 28 W SIXFOLD OUTPUTS
DC-AC INVERTER UNIT
PS-DA0605-02(S) (28 W SIXFOLD OUTPUTS)
(PRELIMINARY INFORMATION)
Input side CN1:
Pin No. Symbols
Ratings
CN 1-1+2+3 Vin
10.8 ~ 13.2 Vdc
CN 1-4+5+6 GND
-
CN 1-7
Vbr
0 ~ 5 Vdc
CN 1-8
Vrm t 0 ~ 1.5 = OFF / 2.5 ~ 5.5 = ON
Output side CN2 ~ CN7
Pin No. Symbols
CN 2-1 Vhigh
CN 2-2
N .C .
CN 2-3
Vlow
Ratings
800 Vrm s (6.0 m Arm s )
-
(GND)
Input side CN8
Pin No. Symbols
Ratings
CN 8-1 Vlam p1 0 ~ 1.5 = OFF / 2.5 ~ 5.0 = ON
CN 8-2 Vlam p2 0 ~ 1.5 = OFF / 2.5 ~ 5.0 = ON
CN 8-3
Vadj
0 ~ 3 Vdc
CN 8-4
GND
-
ELECTRICAL CHARACTERISTICS :
Parameters
Conditions
Sym bols
Vin (V) Vbr (V) Tu (°C)
Specification
Min. Typ. Max.
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
No load Shutdow n
Iout
Iout
Iin
F
Vopen
Ts d
12±1.2
12±0.6
12±1.2
12±1.2
11.4
12±1.2
0.0 -10 ~ +60 5.5
6.0
6.5
5.0 -10 ~ +60 -
18
-
0.0 -10 ~ +60 -
2.3
3.0
0.0 -10 ~ +60 50
53
57
0.0 -10 ~ +60 2.000 2.200 2.400
0.0 -10 ~ +60 1.0
-
-
Unit
m Arm s
%
Adc
kHz
Vrm s
sec
Note
wit hout load
Note 1 :
Note 2:
Note 3:
Note 4:
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked
on mechanical drawing and any conductors.
Vadj = 0V or open, Output Current Max. and Vadj = 3V then Output Current = 3.5 ~ 4.5 mA
Please request fpr other CCFL current.
Before apply any control signal into inverter, please provide Vcc first. Please follow the reversed
sequence during power off. Power off control signal first, then power off Vcc.
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
Info@Power-Systems.de
All specifications are subject to change without notice.
Page (2)
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. : + 49 / 70 62 / 67 59 - 6
Fax: + 49 / 70 62 / 67 59 - 800
Version 1.0.5, 28th February 2008