Input side CN1:
Pin No. Symbols
Ratings
CN 1-1+2+3 Vin
10.8 ~ 13.2 Vdc
CN 1-4+5+6 GND
-
CN 1-7
Vbr
0 ~ 5 Vdc
CN 1-8
Vrm t 0 ~ 1.5 = OFF / 2.5 ~ 5.5 = ON
(PRELIMINARY INFORMATION)
Output side CN2 ~ CN7
Pin No. Symbols
Ratings
CN 2-1 Vhigh 800 Vrm s (6.0 m Arm s )
CN 2-2
Vlow
(GND)
Input side CN8
Pin No. Symbols
Ratings
CN 8-1 Vlam p1 0 ~ 1.5 = OFF / 2.5 ~ 5.0 = ON
CN 8-2 Vlam p2 0 ~ 1.5 = OFF / 2.5 ~ 5.0 = ON
CN 8-3
Vadj
0 ~ 3 Vdc
CN 8-4
GND
ELECTRICAL CHARACTERISTICS :
Parameters
Conditions
Sym bols
Vin (V) Vbr (V) Tu (°C)
Specification
Min. Typ. Max.
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
No load Shutdow n
Iout
Iout
Iin
F
Vopen
Ts d
12±1.2
12±0.6
12±1.2
12±1.2
11.4
12±1.2
0.0 0 ~ +60 5.5
6.0
6.5
5.0 0 ~ +60 -
18
-
0.0 0 ~ +60 -
2.3
3.0
0.0 0 ~ +60 50
53
57
0.0 0 ~ +60 1.550 1.700 2.000
0.0 0 ~ +60 1.0
-
-
Unit
m Arm s
%
Adc
kHz
Vrm s
sec
Note
wit hout load
Note 1 :
Note 2:
Note 3:
Note 4:
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked
on mechanical drawing and any conductors.
Vadj = 0V or open, Output Current Max. and Vadj = 3V then Output Current = 3.5 ~ 4.5 mA
Please request for other CCFL-current.
Before apply any control signal into inverter, please provide Vcc first. Please follow the reversed
sequence during power off. Power off control signal first, then power off Vcc.
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
Info@Power-Systems.de
All specifications are subject to change without notice.