DC-AC INVERTER UNIT
PS-DA0416-01(S) (18 W DUAL OR QUAD OUTPUTS)
Output side CN2 ~ CN5
Pin No. Symbols
Ratings
CN 2-1 Vhigh 620Vrm s (6.0 m Arm s )
CN2-2
N .C .
-
CN 2-3
Vlow
(GND)
(PRELIMINARY INFORMATION)
ELECTRICAL CHARACTERISTICS :
Parameters
Conditions
Sym bols
Vin (V) Vbr (V) Tu (°C)
Specification
Min. Typ. Max.
Output Current
Iout 12±1.2 0.0 -10 ~ +70 5.5
6.0
6.5
Output Current
Iout 12±0.6 5.0 -10 ~ +70 -
15
-
Input Current
Iin 12±1.2 0.0 -10 ~ +70 -
1.67 2.17
Frequency
F
12±1.2 0.0 -10 ~ +70 50
55
60
Open Circuit Voltage Vopen 11.4 0.0 -10 ~ +70 1.550 1.800
-
Unit
m Arm s
%
Adc
kHz
Vrm s
Note
Dut y 100 %
Dut y
Note 1 :
Note 2:
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as
marked on mechanical drawing and any conductors.
Before apply any control signal into inverter, please provide Vcc first. Please follow the reversed
sequence during power off. Power off control signal first, then power off Vcc.
TEST CIRCUIT :
Vin
10.8 ~ 13.2 V
A Iin
V
Vrmt
0 / 3.3 Vdc
V
a
b SW1
F
F
CN1-1
CN1-2
CN1-3
CN1-4
T1
CN1-5
Vbr
0 ~ 5.0 Vdc
N.C.
CN1-6
CN1-7
Vin
10.8 ~ 13.2 V
A Iin
V
CN6-1
CN6-2
CN6-3
CN6-4
Vrmt
0 / 3.3 Vdc
V
a
b SW2
CN6-5
Vbr
0 ~ 5.0 Vdc
N.C.
CN6-6
CN6-7
1000:1
PROBE
SW3
CN2-1
Vopen
V
~
CL1
CN2-2 N.C.
SW4
CN2-3
SW5
CN3-1
RL1
A
~
Iout
1
CN3-2 N.C.
SW6
CN3-3
SW7
CN4-1
RL1
A Iout
~1
CN4-2 N.C.
SW8
CN4-3
SW9
CN5-1
RL1
A
~
Iout
1
CN5-2 N.C.
SW10
CN5-3
RL1
A
~
Iout
1
SW 1
a
b
SW 2
a
b
Operat io o f unit
Op erat io n
No n Op erat io n
Operat io o f unit
Op erat io n
No n Op erat io n
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
Info@Power-Systems.de
All specifications are subject to change without notice.
Page (2)
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. : + 49 / 70 62 / 67 59 - 6
Fax: + 49 / 70 62 / 67 59 - 800
Version 1.1.1, 28th February 2008