English
Language : 

PS-DA0408-01-B Datasheet, PDF (2/4 Pages) Power Systems GmbH+Co.KG – DC-AC INVERTER UNIT 18 W QUAD OUTPUTS
PS-DA0408-01-B(S) (18 W QUAD OUTPUTS)
DC-AC INVERTER UNIT
(PRELIMINARY INFORMATION)
ELECTRICAL CHARACTERISTICS :
Parameters
Conditions
Symbols
Vin (V) Vbr (V) Tu (°C)
Specification
Min. Typ. Max.
Output Current
Iout 12±1.2 0 -10 ~ +60 5.8
6.5
7.0
Output Current
Iout 12±0.6 5.0 -10 ~ +60 -
23
-
Input Current
Iin 12±1.2 0 -10 ~ +60 -
1.61 2.09
Frequency
F 12±1.2 0 -10 ~ +60 45
50
55
Open Circuit Voltage Vopen 11.4
0 -10 ~ +60 1.570 1.700 2.300
Unit
m Arm s
%
Adc
kHz
Vrm s
Note
Duty 100%
Note 1 :
Note 2:
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as
marked on mechanical drawing and any conductors.
Before apply any control signal into inverter, please provide Vcc first. Please follow the reversed
sequence during power off. Power off control signal first, then power off Vcc.
TEST CIRCUIT :
Vbr
0 ~ 5.0 Vdc
Vrmt
0 / 5 Vdc
V
a
b SW1
Vin
10.8 ~ 13.2 Vdc
A Iin
N.C.
V
F
F
CN1-1
CN1-3
CN1-5
CN1-6
CN1-8
CN1-9
CN1-2
T1
CN1-4
CN1-7
CN1-10
CN1-11
CN1-12
1000:1
CN2-1
PROBE
SW3
RL1
Vopen
V
~
CL1
SW4
CN2-2
A
~
Iout
1
SW3
CN3-1
RL1 CL1
SW4
CN3-2
A
~
Iout
1
SW3
CN4-1
RL1 CL1
SW4
CN4-2
A
~
Iout
1
SW3
CN5-1
RL1 CL1
CN5-2 SW4
A
~
Iout
1
SW 1
a
b
Operation of unit
Operation
Non operation
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
Info@Power-Systems.de
All specifications are subject to change without notice.
Page (2)
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. : + 49 / 70 62 / 67 59 - 6
Fax: + 49 / 70 62 / 67 59 - 800
Version 1.0.2, 28th February 2008