English
Language : 

PS-DA0401-01 Datasheet, PDF (2/4 Pages) Power Systems GmbH+Co.KG – DC-AC INVERTER UNIT 20 W QUAD OUTPUTS
DC-AC INVERTER UNIT
PS-DA0401-01(S) (20 W QUAD OUTPUTS)
(PRELIMINARY INFORMATION)
ELECTRICAL CHARACTERISTICS :
Parameters
Conditions
S ym bols
Vin (V) Vbr (V) Tu (°C)
Specification
Min. Typ. Max.
Output Current
Iout 12±1.2 0.0 0 ~ +50 5.5
6.0
6.5
Output Current
Iout 12±0.6 5.0 0 ~ +50 1.7
2.0
2.3
Input Current
Iin 12±1.2 0.0 0 ~ +50 -
1.77 2.2
Frequency
F
12±1.2 0.0 0 ~ +50 45
52
60
Open Circuit Voltage Vopen 11.4 0.0 0 ~ +50 1.300 1.500
-
No load Shutdown
Ts d 12±1.2 0.0 0 ~ +50 1.0
-
-
Unit
m Arm s
m Arm s
Adc
kHz
Vrm s
sec
Note
Duty 100%
wit hout load
Note 1 :
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked
on mechanical drawing and any conductors.
TEST CIRCUIT :
Vin
12 V
Vrmt
0 / 5 Vdc
Iin
A
V
a
V
b SW1
F
F
CN1-1
CN1-2
CN1-3
CN1-4
T1
CN1-5
CN1-6
Vbr
0 ~ 5.0 Vdc
CN1-7
1000:1
PROBE Vopen
V
SW3
~
CN2-1
CN2-2
CN2-4
CN3-1
SW4
RL2
A
~
SW5
RL1
CL2
Iout A
2~
CL1
Iout
1
SW3
CN3-2
CN3-4
SW4
RL2
A
~
SW5
RL1
CL2
Iout A
2~
CL1
Iout
1
SW1
a
b
Operation of unit
Op e ra ti o n
Non operation
Power Systems – The Power Solution
Web:
www.Power-Systems.de
Email:
Info@Power-Systems.de
All specifications are subject to change without notice.
Page (2)
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. : + 49 / 70 62 / 67 59 - 6
Fax: + 49 / 70 62 / 67 59 - 800