English
Language : 

PS-DA0276-01-B Datasheet, PDF (2/4 Pages) Power Systems GmbH+Co.KG – DC-AC INVERTER UNIT 10 W DUAL OUTPUTS
DC-AC INVERTER UNIT
PS-DA0276-01-B(S) (10 W DUAL OUTPUTS)
Input side CN1:
Pin No. Symbols
CN 1-1
Vin
CN 1-2
Vin
CN 1-3 GND
CN 1-4 GND
CN 1-5
Vbr
CN 1-6
Vs t
CN 1-7 Vrm t
Ratings
10,8 ~ 13,2 Vdc
10,8 ~ 13,2 Vdc
0 ~ 3.0 Vdc
N .C .
0 ~ 0.4 = OFF / 2.5 ~ Vin = ON
(PRELIMINARY INFORMATION)
Output side CN2:
Pin No. Symbols
CN 2-1 Vhigh
CN 2-2
N.C.
CN 2-3
GND
Ratings
660 Vrm s (6.5m Arm s )
-
-
Output side CN3:
Pin No. Symbols
CN 3-1 Vhigh
CN 3-2
N .C .
CN 3-3
GND
Ratings
660 Vrm s (6.5 m Arm s )
-
-
ELECTRICAL CHARACTERISTICS :
Parameters
Conditions
Sym bols
Vin (V) Vbr (V) Tu (°C)
Output Current
Iout 12±1.2 0.0
Output Current
Iout 12±0.6 3.0
Input Current
Iin1 12±1.2 0.0
Input Current
Iin2 12±1.2 0.0
Frequency
F
12±1.2 0.0
Open Circuit Voltage Vopen 11.4 0.0
No load Shutdow n
Ts d 12±1.2 0.0
0 ~ +60
0 ~ +60
0 ~ +60
0 ~ +60
0 ~ +60
0 ~ +60
0 ~ +60
Specification
Min. Typ. Max.
6.0
6.5
7.0
15
-
1.1
1.4
-
-
1.0
40
50
55
1.500 1.600
-
-
3.0
-
Unit
m Arm s
%
Adc
m Adc
kHz
Vrm s
sec
Note
Dut y 100 %
Dut y min
wit ho ut lo ad
Note 1 :
Note 2 :
Note 3:
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as
marked on mechanical drawing and any conductors.
Open circuit on all lamps for more than 3 sec., will shut the inverter down.
Before apply any control signal into inverter, please provide Vcc first. Please follow the reversed
sequence during power off. Power off control signal first, then power off Vcc.
TEST CIRCUIT :
SW 1
a
b
Operation of unit
Operation
Non operation
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
Info@Power-Systems.de
All specifications are subject to change without notice.
Page (2)
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. : + 49 / 70 62 / 67 59 - 6
Fax: + 49 / 70 62 / 67 59 - 800