English
Language : 

PS-DA0253-13 Datasheet, PDF (2/4 Pages) Power Systems GmbH+Co.KG – DC-AC INVERTER UNIT 9 W DUAL OUTPUTS
DC-AC INVERTER UNIT
PS-DA0253-13(S) (9 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
ELECTRICAL CHARACTERISTICS :
Parameters
Conditions
S ym bols
Vin (V) Vbr (V) Tu (°C)
Output Current
Iout 5±0.25 0.0
Output Current
Iout 5±0.12 5.0
Input Current
Iin 5±0.25 0.0
Frequency
F
5±0.25 0.0
Open Circuit Voltage Vopen 5±0.25 0.0
No Load Shutdown
Ts d 5±0.25 0.0
0 ~ +50
0 ~ +50
0 ~ +50
0 ~ +50
0 ~ +50
0 ~ +50
Specification
Min. Typ. Max.
5.5
0.8
-
39.0
1.300
-
6.0
2.2
1.72
46.5
1.400
1.0
6.5
2.9
2.25
54.0
1.700
-
Unit
m Arm s
m Arm s
Adc
kHz
Vrm s
sec
Note
wit hout load
Note 1 :
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked
on mechanical drawing and any conductors.
DIMMING CHARACTERISTICS (Reference)
7,0
6,0
5,0
4,0
3,0
2,0
1,0
0,0
0,0
1,0
2,0
3,0
4,0
5,0
Vbr (VDC)
TEST CIRCUIT :
Vin
4.75 ~ 5.25 V
Iin
A
V
Vrmt
0 / 5 Vdc
a
V
b SW1
F
F
CN1-1
CN1-2
CN1-3
CN1-4
T1
CN1-5
Vbr
0 ~ 5.0 Vdc
V
CN1-6
CN1-7
CN2-1
1000:1
PROBE
SW3
Vopen
V
~
CN2-2
SW4
CN3-1
SW5
RL1
A
~
CL1
Iout
1
CN3-2 SW6
RL1
A
~
CL1
Iout
2
SW1
a
b
Operation of unit
Op e ra ti o n
Non operation
Power Systems – The Power Solution
Web:
www.Power-Systems.de
Email:
Info@Power-Systems.de
All specifications are subject to change without notice.
Page (2)
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. : + 49 / 70 62 / 67 59 - 6
Fax: + 49 / 70 62 / 67 59 - 800