English
Language : 

PS-DA0253-03 Datasheet, PDF (2/4 Pages) Power Systems GmbH+Co.KG – DC-AC INVERTER UNIT 9 W DUAL OUTPUTS
DC-AC INVERTER UNIT
PS-DA0253-03(S) (9 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
ELECTRICAL CHARACTERISTICS :
Parameters
Conditions
S ym bols
Vin (V) Vbr (V) Tu (°C)
Output Current
Iout 12±1.2 0.0
Output Current
Iout 12±0.6 1.8
Input Current
Iin 12±1.2 0.0
Frequency
F
12±1.2 0.0
Open Circuit Voltage Vopen 11.4 0.0
No Load Shutdown
Ts d 12±1.2 0.0
0 ~ +50
0 ~ +50
0 ~ +50
0 ~ +50
0 ~ +50
0 ~ +50
Specification
Min. Typ. Max.
5.3
1.3
-
32.5
1.500
1.0
6.0
2.0
0.75
40
1.700
-
6.7
2.7
1.0
47.5
1.900
-
Unit
m Arm s
m Arm s
Adc
kHz
Vrm s
sec
Note
Dut y 100%
wit hout load
Note 1 :
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked
on mechanical drawing and any conductors.
DIMMING CHARACTERISTICS (Reference)
7,0
6,0
5,0
4,0
3,0
2,0
1,0
0,0
0,0
0,4
0,7
1,1
1,4
1,8
Vbr (VDC)
TEST CIRCUIT :
Vin
10.8 ~ 13.2 V
A Iin
V
Vrmt
0 / 5 Vdc
a
V
b SW1
F
F
CN1-1
CN1-2
CN1-3
CN1-4
T1
CN1-5
Vbr
0 ~ 1.8 Vdc
V
c
d SW2
Rbr
0 ~ 10 kOhm
CN1-6
CN1-7
CN2-1
1000:1
PROBE
SW3
Vopen
V
~
CN2-2
N.C.
CN2-3 SW4
CN3-1
SW5
RL1
CL1
A Iout
~1
CN3-2
N.C.
CN3-2 SW6
RL1
CL1
A Iout
~2
SW1
a
b
Operation of unit
Op e ra ti o n
Non operation
SW2
c
b
Operation of unit
Vbr 0 ~ 1.8 Vdc dimming
Rbr 0 ~ 10 kOhm dimming
Power Systems – The Power Solution
Web:
www.Power-Systems.de
Email:
Info@Power-Systems.de
All specifications are subject to change without notice.
Page (2)
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. : + 49 / 70 62 / 67 59 - 6
Fax: + 49 / 70 62 / 67 59 - 800