English
Language : 

PS-DA0224-10 Datasheet, PDF (2/4 Pages) Power Systems GmbH+Co.KG – DC-AC INVERTER UNIT 9 W DUAL OUTPUTS
DC-AC INVERTER UNIT
PS-DA0224-10(S) (9 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
Input side CN1:
Pin No. Symbols
CN 1-1 Vin
CN 1-2 Vin
CN 1-3 GND
CN 1-4 GND
CN 1-5 Vbr
CN 1-6 Vs t
CN 1-7 Vrm t
Ratings
10,8 ~ 13,2 Vdc
10,8 ~ 13,2 Vdc
0 ~ 2.5 Vdc
0 / 5 Vdc
0 ~ 0.4 = OFF / 2.5 ~ Vin = ON
Output side CN2:
Pin No. Symbols
Ratings
CN 2-1 Vhigh 1000 Vrm s (4.5 m Arm s )
CN 2-2
GND
-
Output side CN3:
Pin No. Symbols
Ratings
CN 3-1 Vhigh 1000 Vrm s (4.5 m Arm s )
CN 3-2
GND
-
ELECTRICAL CHARACTERISTICS :
Parameters
Output Current
Output Current
Input Current
Input Current
Frequency
Open Circuit Voltage
Alarm Signal
(Note 3)
S ym bols
Iout
Iout
Iin1
Iin2
F
Vopen
Vs t
Conditions
Vin (V)
Vrmt
(V)
Tu (°C)
12±1.2 5±0.25 -10 ~ +70
12±0.6 5±0.25 -10 ~ +70
12±1.2 5±0.25 -10 ~ +70
12±1.2 5±0.25 -10 ~ +70
12±1.2 5±0.25 -10 ~ +70
11.4 5±0.25 -10 ~ +70
12±1.2 5±0.25 -10 ~ +70
12±1.2 5±0.25 -10 ~ +70
12±1.2 5±0.25 -10 ~ +70
Specification
Min. Typ. Max.
-
4.5
-
-
2.5
-
-
-
1.3
-
-
1.0
40
TBD
55
2.000
-
-
4.5
5.0
5.5
4.5
5.0
5.5
-
0.0
0.5
Unit
m Arm s
m Arm s
Adc
m Adc
kHz
Vrm s
Vdc
Vdc
Vdc
Note
Dut y 100%
Duty min
Lamp1 open
Lamp2 open
N o r mal
Note 1 :
Note 2 :
Note 3 :
Note 4:
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as
marked on mechanical drawing and any conductors.
Open circuit on all lamps for more than 3 sec., will shut the inverter down.
In test circuit; if any switches SW2 or SW4 opens, then the alarm signal will be activated (+5 Vdc)
Before apply any control signal into inverter, please provide Vcc first. Please follow the reversed
sequence during power off. Power off control signal first, then power off Vcc.
TEST CIRCUIT :
Vin
10.8 ~ 13.2 V
A Iin
V
Vbr
0 ~ 2.5 Vdc
Vrmt
0 / 5 Vdc
Vst
5 Vdc V
a
V
b SW1
F
F
CN1-1
CN1-2
CN1-3
CN1-4
T1
CN1-5
CN1-6
CN1-7
1000:1
PROBE Vopen
V
SW2
~
CN2-1
CN2-2
SW3
CN3-1
SW4
RL1
A
~
CL1
Iout
1
CN3-2 SW5
RL1
A
~
CL1
Iout
1
SW1
a
b
Operation of unit
Op e ra ti o n
Non operation
Power Systems – The Power Solution
Web:
www.Power-Systems.de
Email:
Info@Power-Systems.de
All specifications are subject to change without notice.
Page (2)
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. : + 49 / 70 62 / 67 59 - 6
Fax: + 49 / 70 62 / 67 59 - 800