ELECTRICAL CHARACTERISTICS :
Parameters
Output Current
Conditions
Symbols
Vin (V)
Vrmt
Tu (°C)
(V)
Iout 12±1.2 5±0.25 0 ~ +50
Output Current
Iout 12±0.6 5±0.25 0 ~ +50
Input Current
Frequency
Iin 12±1.2 5±0.25 0 ~ +50
F 12±1.2 5±0.25 0 ~ +50
Open Circuit Voltage Vopen 11.4 5±0.25 0 ~ +50
No load Shutdown
Tsd 12±1.2 5±0.25 0 ~ +50
Specification
Min. Typ. Max.
7.0
3.5
-
44.5
1.300
1.0
8.0
4.0
0.93
52
1.500
-
8.5
4.5
1.4
59.5
1.700
-
Unit
m Arm s
m Arm s
Adc
kHz
Vrm s
sec
Note
Vbr = 0 Vdc
Vbr = 4.2 Vdc
wit hout load
Note 1 :
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked
on mechanical drawing and any conductors.
TEST CIRCUIT :
Vin
12 V
Iin
A
V
F
F
CN1-1
CN1-2
Vbr
0 ~ 4.2 Vdc
CN1-3
T1
CN1-4
a
Vrmt
0 / 5 Vdc
V
b SW1
CN1-5
1000:1
PROBE
CN2-1
SW3
Vopen
V
~
RL1
CL1
CN2-2 SW4
A
~ Iout1
SW5
CN3-1
RL2
CL2
CN3-2
SW6
A
~ Iout2
SW 1
a
b
Operation of unit
Operation
Non operation
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
Info@Power-Systems.de
All specifications are subject to change without notice.
Page (2)
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. : + 49 / 70 62 / 67 59 - 6
Fax: + 49 / 70 62 / 67 59 - 800
Version 1.0.2, 7th July 2008