DC-AC INVERTER UNIT
PS-DA0203-03(S) (9 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
ELECTRICAL CHARACTERISTICS :
Parameters
Conditions
S ym bols
Vin (V) Vbr (V) Tu (°C)
Specification
Min. Typ. Max.
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
No load Shutdown
Iout
Iout
Iin
F
Vopen
Ts d
12±1.2
12±0.6
12±1.2
12±1.2
11.4
12±1.2
0.0 -10 ~ +70 4.75
5.0
5.25
3.3 -10 ~ +70 1.75
2.0
2.25
0.0 -10 ~ +70 -
0.64 0.83
0.0 -10 ~ +70 45
50
55
0.0 -10 ~ +70 1.000 1.200 1.500
0.0 -10 ~ +70 1.0
-
-
Unit
m Arm s
m Arm s
Adc
kHz
Vrm s
sec
Note
Dut y 100%
wit hout load
Note 1 :
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked
on mechanical drawing and any conductors.
TEST CIRCUIT :
F
F
Vin
10.8 ~ 13.2 V
A Iin
V
CN1-1
CN1-2
CN1-3
CN1-4
a
T1
Vrmt
0.5 / 2.5 Vdc
V
b SW1
CN1-5
Vbr
0 ~ 3.3 Vdc
CN1-6
CN1-7
1000:1
PROBE
Vopen
V
~
CN2-1
CN2-2
CN2-4
SW2
SW3
RL2
RL1
CL2
CL1
A
A
Iout
2
~
~
Iout1
SW4
SW1
a
b
Operation of unit
Op e ra ti o n
Non operation
Power Systems – The Power Solution
Web:
www.Power-Systems.de
Email:
Info@Power-Systems.de
All specifications are subject to change without notice.
Page (2)
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. : + 49 / 70 62 / 67 59 - 6
Fax: + 49 / 70 62 / 67 59 - 800
Version 1.7.3, 23th March 2007