DC-AC INVERTER UNIT
PS-DA0201-03(S) (10 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
ELECTRICAL CHARACTERISTICS :
Parameters
Conditions
Specification
Symbols
Unit
Vin (V) Vbr (V) Tu (°C) Min. Typ. Max.
Note
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
No load Shutdown
Iout
Iout
Iin
F
Vopen
Tsd
12±1.2
12±0.6
12±1.2
12±1.2
11.4
12±1.2
0.0 0 ~ +60 5.4
6.0
6.6 mArms
2.5 0 ~ +60 -
20
-
%
0.0 0 ~ +60 -
0.88 1.2
Adc
0.0 0 ~ +60 45
50
55
kHz
0.0 0 ~ +60 1.300 1.500 1.900 Vrms
0.0 0 ~ +60 -
1.0
-
sec
Duty 100%
Duty Min
without load
Note 1 :
Note 2:
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as
marked on mechanical drawing and any conductors.
Before apply any control signal into inverter, please provide Vcc first. Please follow the reversed
sequence during power off. Power off control signal first, then power off Vcc.
TEST CIRCUIT :
Vin
12 V
Iin
A
V
Vrmt
0.4 / 5 Vdc
V
a
b SW1
Vbr
0 ~ 2.5 Vdc
N.C.
F
F
CN1-1
CN1-2
T1
CN1-3
CN1-4
CN1-5
1000:1
PROBE
CN2-1
SW3
Vopen
V
~
RL1
CL1
CN2-2 SW4
A
~ Iout1
SW5
CN3-1
RL2
CL2
CN3-2
SW6
A
~ Iout2
SW 1
a
b
Operation of unit
Operation
Non operation
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
Info@Power-Systems.de
All specifications are subject to change without notice.
Page (2)
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. : + 49 / 70 62 / 67 59 - 6
Fax: + 49 / 70 62 / 67 59 - 800
Version 1.0.3, 7th July 2008