English
Language : 

PS-DA0140-01 Datasheet, PDF (2/2 Pages) Power Systems GmbH+Co.KG – DC-AC INVERTER UNIT 8 W SINGLE OUTPUT
DC-AC INVERTER UNIT
PS-DA0140-01(S) (8 W SINGLE OUTPUT)
Input side CN1:
Pin No. Symbols
Ratings
CN 1-1
Vin
10.8 ~ 13.2 Vdc
CN 1-2
Vin
10.8 ~ 13.2 Vdc
CN 1-3
Vrm t 0 ~ 0.4 = OFF / 2.5 ~ 5.0 = ON
CN 1-4
Vbr
0 ~ 5.0 Vdc
CN 1-5
GND
-
CN 1-6
GND
-
Output Current Select Control
Jumper JP 1 JP 2 JP 3
Short
Short
Short
Short
Output Current
(± 0.5 mArms)
3.5 m Arm s
4.0 m Arm s
5.0 m Arm s
6.0 m Arm s
(PRELIMINARY INFORMATION)
Output side CN2
Pin No. Symbols
Ratings
CN 2-1 Vhigh 1.000 Vrm s (6.0 m Arm s )
CN 2-2
N .C .
-
CN 2-3
Vlow
(GND)
Crosslist:
Displays
TX14D11VM1
TX14D12VM1
TX14D14V M 1B A A
TX16D11VM2
TX18D16VM1CAB
TX20D16VM2
TX23D11VM2
TX23D12VM0
J um pe r
JP 1
JP 2
JP 2
JP 2
NO JP
NO JP
JP 3
JP 3
= JUMP (SHORT J1=Short 1-2, J2=Short 3-4, J3=Short 5-6)
ELECTRICAL CHARACTERISTICS : (for 6mArms selection)
Parameters
Conditions
Symbols
Vin (V) Vbr (V) Tu (°C)
Specification
Min. Typ. Max.
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
No Load Shotdown
Iout
Iout
Iin
F
Vopen
Ts d
12±1.2
12±0.6
12±1.2
12±1.2
11.4
12±1.2
0.0 -10 ~ +60 5.5
6.0
6.5
5.0 -10 ~ +60 -
20
-
0.0 -10 ~ +60 -
0.67 0.75
0.0 -10 ~ +60 50
60
70
0.0 -10 ~ +60 2.200 2.400 2.700
0.0 -10 ~ +60 1.0
-
-
Unit
m Arm s
%
Adc
kHz
Vrm s
sec
Note
Duty 100%
without load
Note 1 :
Note 2:
Note 3:
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked
on mechanical drawing and any conductors.
Open circuit on all lamps for more than 3 sec., will shut the inverter down.
Before apply any control signal into inverter, please provide Vcc first. Please follow the reversed
sequence during power off. Power off control signal first, then power off Vcc.
TEST CIRCUIT :
Vin
10.8 ~ 13.2 Vdc
Iin
A
V
Vrmt
0.4 / 2.5 Vdc
V
a
b SW1
F
F
CN1-1
CN1-2
CN1-3
T1
Vbr
0 ~ 5 Vdc
CN1-4
CN1-5
CN1-6
1000:1
PROBE
CN2-1
SW3
Vopen
V
~
CN2-2
N.C.
CN2-3 SW4
RL1
CL1
A
~ Iout1
SW 1
a
b
Operation of unit
Operation
Non operation
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
Info@Power-Systems.de
All specifications are subject to change without notice.
Page (2)
Address: Hauptstraße 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. : + 49 / 70 62 / 67 59 - 6
Fax: + 49 / 70 62 / 67 59 - 800
Version 1.0.3, 13th January 2010