English
Language : 

CWS-1202.5A10M Datasheet, PDF (1/4 Pages) Power Systems GmbH+Co.KG – DC-DC Converter UNIT
DC-DC Converter UNIT
CW SERIES (10W~12W Wide Input Range)
FEATURES
•10W to 12W dil package
•9-18V, 18-36V, 36-72V Wide Input Range
•100% Burned in
•High efficiency
•UL 94V-0 Package material
•Costum solutions available
•RoHS compliant
•3 Years warranty
OUTPUT SPECIFICATIONS
Voltage Set point Accuracy
Temperature Coefficient
Ripple & Noise (20MHz BW)1
Line Regulation2
Load Regulation3
Minimum Load
Short Circuit Protection
Short Circuit Restart
Transient Response5
Over Load Protection
+/-2% max
+/-0.05%/ °C
100mVp-p max
+/-0.5% max
+/-0.5% max
20% of Full Load
Continuous
Automatic
350uS max
100% ~180%
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature
Storage Temperature
Case Temperature
-40 °C to +85 °C
-55 °C to +105 °C
95% °C max
Humidity
95% max
Cooling
Free-Air Convection
INPUT SPECIFICATIONS
Input Voltage Range
Input Filter
Protection
2:1 Input Range
Pi Network
Fuse Recommended
GENERAL SPECIFICATIONS
Efficiency
Isolation Voltage4
Isolation Resistance
Isolation Capacitance
Switching Frequency
MTBF6
Weight
Case Material
Case Size
Potting Material
Conducted Emissions
Radiated Emissions
Remote On / Off
-On
-Off
-Off idle current
78% min
1500 VDC min
109 ohms min
2200pF max
400 KHz Typ
>600,000 Hours
18.5g Typ
Five-sided shield case
31.8mm*20.3mm*12.2mm
Epoxy (UL94-V0)
EN55022 Class A
EN55022 Class A
3.0…12V/DC or open circuit
(referenced to-Vin)
0…1.2V/DC or short circuit
(pin 1 and pin 2/3)
2.5 mA
ALL SPECIFICATIONS TYPICAL AT NOMINAL LINE, FULL LOAD , AND 25 °C UNLESS OTHERWISE NOTED.
[1] Measured with 1uF ceramic capacitor connect to the output pins.
[2] High Line to Low Line.
[3] Load Regulation is for output load current change from 20% to 100%.
[4] 1500Vdc for 10 seconds
[5] 25% Step Load Change.
[6] MIL-HDBK-217F @25 °C , Ground Benign.
Power Systems – The Power Solution
Web:
www.Power-Systems.de
Email:
Info@Power-Systems.de
All specifications are subject to change without notice.
Page (1)
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. : + 49 / 70 62 / 67 59 - 6
Fax: + 49 / 70 62 / 67 59 - 800
Version 1.0, 20th May 2008