English
Language : 

SFP650-12BG Datasheet, PDF (5/9 Pages) Power-One – AC-DC Front-End 12V Output, 650 Watts
SFP650-12BG AC-DC Front-End Data Sheet
12V Output, 650 Watts
Environmental Specifications
Parameter
Conditions/Description
Altitude
Operating.
Non-Operating.
Operating
Temperature
Internal DC fan for cooling. At 100% load:
Storage Temperature
Temperature
Coefficient
0 ºC to 45 ºC (after 15-minute warm-up).
Relative Humidity
Non-condensing.
Shock
Operating: half-sine, 10 ms, 3-axis.
Vibration
Non-Operating: half-sine, 10 ms, 3-axis.
Operating: swept sine 5-2000-5 Hz, 5-32 Hz,
0.02îDA, 32-2000 Hz.
Non-operating: random 10-2000 Hz.
Min.
0
-40
Nom.
Max.
10K
40K
50
85
0.02
95
+20
+40
1
6.15
Units
ASL ft
ASL ft
ºC
ºC
%/ºC
%RH
Gpk
Gpk
Gpk
Grms
Reliability
Parameter
MTBF
Conditions/Description
(Calculated) MILHDBK 217F Ground Benign.
Demonstrated.
Useful Life.
Min.
100 000
200 000
10
Nom.
Max.
Units
hrs
hrs
yrs
LED Indicators
Indicatorr
Power Good
AC OK
FAIL
LED Color
GREEN
GREEN (Input > 85 VAC
AMBER
FEB 21, 2007
Page 5 of 9
www.power-one.com