English
Language : 

FNP600_10 Datasheet, PDF (5/15 Pages) Power-One – 600-to-5000-Watt Front-End Power Solutions
FNP600/850/1000 AC-DC Front-Ends
& FNR-5-12G/FNR-5-48G Power Shelves Data Sheet
Safety, Regulatory, and EMI Specifications
Parameter
Agency Approvals
Electromagnetic
Interference
Harmonics
Voltage Fluctuation
and Flicker
ESD Susceptability
Radiated
Susceptability
EFT/Burst
Input Transient
Protection
RF Conducted
Disturbances
Voltage Interruptions
Voltage Sag Immunity
Leakage Current
Conditions/Description
Min.
Nom.
Max.
UL60950-1 (UL), CSA C22.2 60950-1 (cUL), EN60950-1 (TUV), IEC60950-1 and CE (LVD)
FCC CFR title 47 Part 15
Sub-Part B,
EN55022/CISPR 22.
Conducted:
B
Radiated:
A
Per IEC61000-3-2.
A
Per IEC61000-3-3.
Pass
Per EN61000-4-2, Level 4. Criterion B
8
.
Per EN 61000-4-3, Level 3. Criterion A
10
.
Per EN 61000-4-4, Level 4. Criterion B
±4
.
Per EN 61000-4-5, Class 3. Criterion B Line-to-Line:
1
.
Line-to-Ground:
2
Per EN 61000-4-6, Level 3. Criterion A
10
.
Per EN 61000-4-11, performance criterion B 30%.
10
.
Per EN 61000-4-11, performance criterion C 60%.
100
Per EN 61000-4-11, performance criterion C 95%.
5
Per SEMI F47-0999 > 100 VAC.
.
No output voltage interruption.
Per EN60950-1.
At 240 VAC:
3.5
Units
Class
Class
kV
V/M
kV
kV
V
ms
ms
Sec
mA
Environmental Specifications
Altitude
Parameter
Operating Temperature
FNP600-12:
FNP850-12:
FNP600-48:
FNP1000-48:
FNP850-12R:
Storage Temperature
Temperature Coefficient
Relative Humidity
Shock
Vibration
Conditions/Description
Operating.
Non-Operating.
Min.
Nom.
Max.
10K
40K
Units
ASL ft
ASL ft
Internal DC fan for cooling. At 100% load:
0
At 50% load:
0
50
ºC
70
Internal DC fan for cooling. At 100% load:
0
At 94% load:
0
At 50% load:
0
-40
0 ºC to 70 ºC (after 15-minute warm-up).
Non-condensing
Operating: half-sine, 10 ms, 3-axis.
Non-Operating: half-sine, 10 ms, 3-axis.
Operating: swept sine 5-2000-5 Hz, 5-32
Hz, 0.02îDA, 32-2000 Hz.
Non-operating: random 10-2000 Hz.
40
50
ºC
70
85
ºC
0.02
%/ºC
95
%RH
+20
Gpk
+40
Gpk
1
Gpk
6.15 Grms
Reliability
Parameter
MTBF
Conditions/Description
(Calculated) MILHDBK 217F Ground Benign.
Demonstrated.
Useful Life.
Min.
100 000
250 000
10
Nom.
Max.
Units
hrs
hrs
yrs
BCD20034-G Rev. AD, 11-May-10
Page 5 of 15