English
Language : 

FNP300-1012_10 Datasheet, PDF (4/6 Pages) Power-One – FNP300 AC DC Power Supply DATA Sheet 12V 24V 48V Output 300 Watts
FNP300 AC-DC Power Supply Data Sheet
12V, 24V, 48V Output, 300 Watts
Protection
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.
Parameter
Input Fuse
Input Transient Protection
Output
Overvoltage Protection
Overtemperature Protection
Conditions/Description
Min
Not user accessible
With varistor
No-load and short circuit proof
short circuit proof
overload (latch style)
110
Latch style
Latch style
Latch style
FNP300-1012 115
FNP300-1024 115
FNP300-1048 115
Automatic power shutdown at TC = 95 °C
Nom Max Units
6.3AT
130
130
130
122
% Io nom
% Io nom
% Io nom
% Vo nom
% Vo no
% Vo no
Control
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.
Parameter
I2C Digital Bus
PS Seated Signal
PS Remote Shutdown
AC fail pre-warning (I2C & OC)*
DC fail (I2C & OC)*
Temperature Warning (I2C & OC)*
Fan OK (I2C & OC)*
Current Share
Status Indication
Conditions/Description
Reports information and monitors alarm functions
Contact closure to GND
TTL compatible signal, open collector. Power supply enabled at Low or TTL "0"
(e.g. by connecting of pin 22 to 0V or GND), and
inhibited to latching mode** at High or TTL "1", or leave it open.
Supervisory AC input voltage;
Pre-warning time >6 ms
Supervisory under- and overvoltage pre-ORing diode of V1
Indicates if unit is operating normally or in overtemperature,
Pre-warning time >10 ms
Indicates if fan is operating or has failed
Droop load characteristic for V1 and V2
LEDs: DC OK (green), AC OK (green)
* Signal provided by I2C interface or by open collector (OC)
** (1) Standard FNP300 models (without "H" at the end of part number) have latching inhibit function, i.e., once PSU is
inhibited, it needs input power re-cycle to allow using enable state again.
(2) FNP300 variants marked with "H" character do have non-latching inhibit function so there's no need to
re-cycle input power when enabling unit after inhibit state.
Features
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.
Parameter
Fan speed control
µC supply voltage in-/output
(Pin 10)
Conditions/Description
4 fan speed levels depending on inlet temperature
Fan speed level and temperature information available on I2C digital bus
If unit is operating: 5 to 7V is provided at pin 10.
If unit is NOT operating, pin 10 is input from a parallel connected unit for µC supply.
BCD20015-G Rev. AB, 29-Mar-10
Page 4 of 6
www.power-one.com