English
Language : 

LOK4240-2RLDG Datasheet, PDF (3/10 Pages) Power-One – LOS, LOR, LOK4000 Series Data Sheet DIN-Rail Mountable AC-DC (DC-DC) Converters
LOS, LOR, LOK4000 Series Data Sheet
®
DIN-Rail Mountable AC-DC (DC-DC) Converters
Functional Description
The Convert Simply 15, 30, and 50 watt front-end modules are
flyback converters with a fixed frequency of 100 kHz (LOK) or
130 kHz (LOR, LOS). The battery charger modules and the
LOK4001-2RLD have a rectangular V/I output characteristic.
The rectifier modules have overload protection working in a
hiccup mode.
03094
03095
L1
2
N3
opt. F
NTC
4 Vo+
5 Vo+
6 Vo–
7 Vo–
8R
Fig. 1
Block diagram LOK4301, LOK4601 and 4801 (rectifier
versions), all LOR and all LOS.
L1
2
N3
opt. F
NTC
5 Vo+
6 Vo–
7 Vo–
8R
4D
Fig. 2
Block diagram LOK4140, LOK4240 and LOK4740 (battery
charger versions) and LOK4001- 2RLD.
Electrical Input Data
General Condition: TA = 25 °C unless otherwise specified
Table 2: Input data
Characteristics
Vi rated Rated input voltage range
Vi nom Nominal input voltage
Vi
Operating input voltage range
fi
Ii
l i nl
l inr max
Nominal line frequency
Input current at 115 / 230 VAC 1
Input current at 230 VAC and no load
Peak inrush current at Vi = 230 V 2
LOS
100 - 240
230
85 - 264
90 - 250
50 - 60
0.3/0.15
18
1 At Io nom.
2 Inrush current limitation by a 16 Ω NTC resistor.
LOR
100 - 240
230
85 - 264
90 - 250
50 - 60
0.52/ 0.26
18
LOK
100 - 240
230
85 - 264
90 - 250
50 - 60
0.8/0.4
0.035
19
Unit
VAC
VDC
Hz
A
BCD20035-G Rev AB, 23-Jun-2011
Page 3 of 10
www.power-one.com