English
Language : 

MAP40 Datasheet, PDF (2/3 Pages) Power-One – Wide Range Input for 110/220 VAC Applications
MAP55 SERIES
INPUT SPECIFICATIONS
PARAMETER
Input Voltage - AC
CONDITIONS/DESCRIPTION
Continuous input range.
Input Frequency
Brown Out Protection
Hold-up Time
Input Current
Input Protection
Inrush Surge Current
Operating Frequency
AC input.
Lowest AC input voltage that regulation is maintained with full rated loads.
Nominal AC Input Voltage (115VAC), full rated load.
90 VAC (55W load).
Non-user serviceable internally located AC input line fuse.
Internally limited by thermistor. Vin = 264VAC (one cycle). 25° C.
Switching frequency of power supply (varies with load).
MIN
NOM
MAX
UNITS
90
132
VAC
175
264
47
63
Hz
90
VAC
20
ms
1.6
ARMS
38
APK
22
180
kHz
OUTPUT SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
Efficiency
Full load, 115VAC. Varies with distribution of loads among outputs.
73
Minimum Loads
MAP55-1012
0.21
MAP55-1024
0.11
MAP40-1005 and all multiple output models, main channel only.
0.50
Ripple and Noise
Full load, 20MHz bandwidth.
Output Power
Continuous output power, all multiple output models.
Peak output power (60s maximum, 10% duty cycle), all multiple output models.
Overshoot / Undershoot
Output voltage overshoot/undershoot at turn-on, V1, V2.
Regulation
Varies by output. Total regulation includes: line changes from 90-132 VAC or 175-264 VAC,
changes in load starting at 20% load and changing to 100% load.
Transient Response
Recovery time, to within 1% of initial set point due to a 50-100%
load change, 4% max. deviation. (Main output of multiple output units).
Turn-on Delay
Time required for initial output voltage stabilization.
1
Turn-on Rise Time
Time required for output voltage to rise from 10% to 90% (Note 1).
NOTES: 1) Nominal rise time for MAP55-1024 is 36 msec.
NOM
MAX
UNITS
%
Amps
See Model Selection Chart.
55
Watts
65
Watts
1
%
See Model Selection Chart.
500
µs
4
Sec
7
ms
INTERFACE SIGNALS AND INTERNAL PROTECTION
PARAMETER
Overvoltage Protection
Overload Protection
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
MAP40-1005
5.5
6.8
MAP55-1012
17.5
19.7
MAP55-1024
32.0
36.0
Main output only of multiple output units.
5.6
6.8
Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.
UNITS
V
SAFETY, REGULATORY, AND EMI SPECIFICATIONS
PARAMETER
Agency Approvals
Dielectric Withstand
Voltage
Electromagnetic
Interference,
Conducted
Insulation Resistance
Leakage Current
CONDITIONS/DESCRIPTION
UL1950.
CSA 22.2 No. 234/950.
EN60950 (TUV).
Input to output.
FCC CFR title 47 Part 15 Sub-Part B - conducted & radiated.
EN55022 / CISPR 22 conducted.
EN55022 / CISPR 22 radiated.
Input to output.
Per EN60950, 264VAC.
MIN
2600
B
B
A
7
NOM
MAX
Approved.
500
UNITS
VDC
Class
MΩ
µA
2