PLP75 Datasheet, PDF (1/6 Pages) Power-One – AC-DC power supplies suited for telecom | |||
|
PLP75 AC-DC Series Data Sheet
75 Watts
Applications
⢠Telecom, datacom
⢠Networking
⢠Industrial
⢠Medical instrumentation
⢠Consumer
⢠Gaming
Features
⢠RoHS compliant for all six substances
⢠75 Watts with 5 CFM forced-air cooling
⢠Typical 80% efficiency
⢠65 Watts with convection cooling
⢠85-264 VAC wide-range input
⢠FCC & CISPR 22, Class "B" â Conducted EMI
⢠Power Factor Corrected (meets IEC61000-3-2)
⢠Typical 0.99 power factor
⢠Height meets 1U chassis constraints
⢠Two-year limited warranty
⢠Safety Agency pending to UL60960-1, CSA 22.2No.
60950-1-03, and TUV EN60950/IEC 60950-1
⢠Compliance with EN 61000-4-2 level 4 (ESD),
EN 61000-4-3 (RF), EN 61000-4-4 level 3 (Fast
Transient/Burst), EN 61000-4-5 class 3 (Surge)
Description
The PLP75 is a cost-effective and efficient series of AC-DC power supplies suited for telecom, datacom, and many
other applications. The PLP75 Series meets the international information technology safety standards with the CE-
Mark for the European Low Voltage Directive (LVD). Active power-factor-correction (PFC) is a standard feature.
PFC enables the user to comply with EN 61000-3-2 line harmonics requirements. In addition, PFC reduces line
losses and rms input current to help achieve low-cost operation and makes the end product more environmentally
friendly to the end users.
Single-Output Model Selection
Model
PLP75-1003G
PLP75-1005G
PLP75-1012G
PLP75-1024G
PLP75-1048G
Nominal
Output Voltage
(VDC)
3.3 5
55
12 5
24 5
48 5
Min-Max Output
Current (Amps),
Convection
0.2 - 13
0.2 - 13
0.1 - 5.4
0.1 - 2.7
0.1 - 1.4
Min-Max Output
Current (Amps),
Forced Air 1
0.2 - 15
0.2 - 15
0.1 - 6.5
0.1 - 3.1
0.1 - 1.6
Peak Output
Current
(Amps) 2
17.5
16.5
7
3.5
1.8
Total
Regulation
(%) 3
±2
±2
±2
±2
±2
Ripple &
Noise
pk-pk % 4
1
1
1
1
1
1 5 CFM or 150 LFM (average measurement of six equally-distributed points through a 3.5" x 1.6" (9 cm x 4 cm cross-sectional area) with power
supply mounted on a 0.25" (6.35 mm) standoffs. Recommended airflow direction is from the AC side to the DC side.
2 Peak current duration for less than 30 seconds with a maximum duty cycle of 10%.
3 At 25 °C ambient including voltage set point tolerance, line and load regulation
4 Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
5 Output is adjustable ±10 % of nominal.
DEC 04, 2006 revised to JAN 30, 2007
Page 1 of 6
www.power-one.com
|
▷ |