|
NET1_05 Datasheet, PDF (1/4 Pages) Power-One – AC-DC Series | |||
|
NET1 AC-DC Series Data Sheet
Features
⢠Currents over 100 Amps
⢠Fits 1U chassis height constraints
⢠No minimum load requirement
⢠Current-share capabilities on all outputs
⢠Patented high-efficiency design
⢠Meets European power factor requirements
⢠Excellent load transient response
Description
Designed to meet the stringent requirements of todayâs high-speed datacom and telecom circuitry, Power-Oneâs NET1
Series is an excellent compact power solution for low-voltage, high-current applications. The NET1âs high efficiency is
achieved through the use of synchronous rectification and a newly-patented âSoft Transition Forward Converterâ.
The NET1âs rectification method lowers output losses, reduces system cooling requirements (allowing greater power
in a smaller package), and eliminates minimum-load requirements.
Advanced surface-mount design and packing technology reduce the NET1âs height to 1.35â (34.3mm) to fit in 1U
applications. NET1âs high-performance active power factor circuitry meets EN61000-3-2 requirements for compliance
with European Power Line Harmonic Requirements for 2001. A multifunctional output terminal allows connection to #8
ring lugs, 0.25â quick disconnects, cable connectors, and PCB-mounted connectors.
Multiple-Output Model Selection â 240W WITH 300 LFM FORCED AIR COOLING
MODEL
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
OUTPUT
CURRENT (NOTE 1)
LINE
REGULATION
+3.3V
+0.5V
50A
0.2%
NET1-4350
+12V
+12V
FIXED
FIXED
4A
0.2%
4A
0.2%
+5V
+0.5V
30A
0.2%
+3.3V
+0.5V
50A
0.2%
NET1-4230
+5V
+12V
FIXED
FIXED
5A
0.2%
4A
0.2%
+2.5V
+0.5V
50A
0.2%
+3.3V
+0.5V
50A
0.2%
NET1-4130
+5V
+12V
FIXED
FIXED
5A
0.2%
4A
0.2%
+1.8V
+0.5V
50A
0.2%
+1.8V
+0.5V
50A
0.2%
NET1-4112
+12V
+12V
FIXED
FIXED
4A
0.2%
4A
0.2%
+1.5V
+0.5V
50A
NOTES: 1) Output currents ratings are expressed with 300 LFM forced air @ 18 CFM.
2) Maximum peak-to-peak noise for a 20 MHz bandwidth.
0.2%
Model numbers highlighted in yellow or shaded are not recommended for new designs.
LOAD
REGULATION
1%
3%
3%
1%
1%
3%
3%
1%
1%
3%
3%
1%
1%
3%
3%
1%
RIPPLE & NOISE
Pk-Pk (NOTE 2)
50mV
120mV
120mV
50mV
50mV
50mV
120mV
50mV
50mV
50mV
120mV
50mV
50mV
120mV
120mV
50mV
INITIAL SETTING
ACCURACY
± 30mV
± 100mV
± 100mV
± 50mV
± 20mV
± 50mV
± 100mV
± 20mV
± 30mV
± 50mV
± 100mV
± 20mV
± 20mV
± 100mV
± 100mV
± 20mV
MAY 18, 2005 revised to APR 05, 2006
Page 1 of 4
www.power-one.com
|
▷ |