English
Language : 

NET1 Datasheet, PDF (1/3 Pages) Power-One – Currents Over 100 Amps
NET1 SERIES
AdvaRnceeledasPeroduct
Designed to meet the stringent requirements of today’s high-speed
datacom and telecom circuitry, Power-One’s NET1 series is an excellent
compact power solution for low-voltage, high-current applications. The
NET1’s high efficiency is achieved through the use of synchronous
rectification and a newly-patented “Soft Transition Forward Converter”.
The NET1’s rectification method lowers output losses, reduces system
cooling requirements (allowing greater power in a smaller package), and
eliminates minimum load requirements.
Advanced surface-mount design and packing technology reduce the
NET1’s height to 1.35” (34.3mm) to fit in 1U applications. NET1’s
high-performance active power factor circuitry meets EN61000-3-2
requirements for compliance with European Power Line Harmonic
Requirements for 2001. A multifunctional output terminal allows
connection to #8 ring lugs, 0.25” quick disconnects, cable connectors,
and PCB-mounted connectors.
FEATURES
• Currents Over 100 Amps
• Fits 1U Chassis Height Constraints
• No Minimum Load Requirement
• Current Share Capabilities on All Outputs
• Patented High-Efficiency Design
• Meets European Power Factor Requirements for 2001
• Excellent Load Transient Response
MULTIPLE OUTPUT MODEL SELECTION CHART – 240W WITH 300 LFM FORCED AIR COOLING
MODEL
NET1-4325
NET1-4130
OUTPUT
VOLTAGE
+3.3V
+2.5V
+5V
+12V
+1.8V
+3.3V
+5V
+12V
ADJUSTMENT
RANGE
+0.5V
+0.5V
FIXED
FIXED
+0.5V
+0.5V
FIXED
FIXED
OUTPUT
CURRENT (NOTE 1)
50A
50A
5A
4A
50A
50A
5A
4A
LINE
REGULATION
0.2%
0.2%
0.2%
0.2%
0.2%
0.2%
0.2%
0.2%
LOAD
REGULATION
1%
1%
3%
3%
1%
1%
3%
3%
NET1-4112
+1.8V
+1.65V
+5V
+12V
+0.5V
+0.5V
FIXED
FIXED
50A
0.2%
1%
50A
0.2%
1%
5A
0.2%
3%
4A
0.2%
3%
NOTES: 1) Output currents ratings are expressed with 300 LFM forced air.
2) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
RIPPLE & NOISE
%Pk-Pk (NOTE 2)
1% or 50mV
1% or 50mV
1% or 50mV
1% or 50mV
1% or 50mV
1% or 50mV
1% or 50mV
1% or 50mV
1% or 50mV
1% or 50mV
1% or 50mV
1% or 50mV
INITIAL SETTING
ACCURACY
± 30mV
± 30mV
± 30mV
± 100mV
± 20mV
± 30mV
± 30mV
± 100mV
± 20mV
± 30mV
± 30mV
± 100mV
INPUT SPECIFICATIONS
PARAMETER
Input Voltage - AC
Input Frequency
Hold-up Time
Input Current
Input Protection
Inrush Surge Current
Power Factor
CONDITIONS/DESCRIPTION
Continuous input range.
AC input.
After last AC line peak at 240 watts.
85 VAC at full rated load.
Non-user serviceable internally located AC input line fuse.
Internally limited by thermistor. Vin = 220 VAC, one cycle, 25°C.
Per EN61000-3-2.
MIN
TYP
MAX
UNITS
85
264
VAC
47
63
Hz
20
mS
4.0
ARMS
35
APK
0.95
W/VA
Rev. 11/2000