MAP140-1012 Datasheet, PDF (1/4 Pages) Power-One – a full range of options and up to 30 watts more power than comparable products in this industry-standard footprint.
MAP140 AC-DC Series Data Sheet
Features
• RoHS lead-solder-exempt compliant
• Universal input 85-264 VAC
• Input transient & ESD compliance to EN61000-4-2/-3/-4
• CE marked to Low Voltage Directive
• Industry-standard footprint: 7.00" x 4.30" x 1.80"
(177.8mm x 109.2mm x 45.7mm)
• Remote sense and overvoltage protection
• Power Fail signal standard on MAP140-3000P, optional
on MAP140-1012 and MAP140-1024
• Optional overtemperature protection, L-bracket, and cover
Description
Power-One’s MAP140 Series provides a full range of options and up to 30 watts more power than comparable
products in this industry-standard footprint. With a universal input from 85 to 264 VAC and power densities up to 2.6
watts/inch3, the MAP140 meets the most rigorous requirements of commercial, industrial, and datacom systems.
Rated for use in convection and forced-air cooled (200 LFM) applications, the MAP140 delivers dependable power
with a Mean Time Between Failures (MTBF) in excess of 180,000 hours. In addition to UL, CSA, and TÜV regulatory
compliance, the MAP140 displays the CE Mark.
Single Output Model Selection
MODEL
OUTPUT
VOLTAGE
MAP140-1012 12V/15V
MAP140-1024 24V/28V
MAP140-1048 48V
ADJUSTMENT
RANGE
11.0V to 16.0V
22.8V to 29.2V
45.6V to 54.0V
CONVECTION
COOLED CURRENT
9.2/7.3A (Note 2)
4.6/4A (Note 2)
2.3A
FORCED AIR
CURRENT (NOTE 3)
12.5A/10A (Note 2)
6.3A/5.4A (Note 2)
3.1A
LINE
REGULATION
0.1%
0.1%
0.1%
LOAD
REGULATION
0.5%
0.5%
0.5%
RIPPLE & NOISE
%p-p (NOTE 1)
1%
1%
1%
INITIAL SETTING
ACCURACY
11.97V to 12.03V
23.95V to 24.05V
47.9V to 48.1V
NOTES: 1) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
2) MAP140-1012 output currents are expressed as 12V/15V operation. MAP140-1024 output currents are expressed as 24V/28V operation.
3) With 200 LFM forced air cooling.
Multiple Output Model Selection – 80W Convection Cooled, 140W Forced-Air Cooled (200 LFM)
MODEL
OUTPUT
VOLTAGE
+5V
MAP140-3000P +12V
-12V
ADJUSTMENT
RANGE
4.75 - 5.25V
Fixed
Fixed
OUTPUT
CURRENT (NOTE 1)
16A/25A
4A/9A PK
1A/1.5A PK
PEAK OUTPUT
CURRENT (NOTE 1)
20A/25A PK
4A/9A PK
1A/1.5A PK
LINE
REGULATION
0.2%
0.1%
0.1%
LOAD
REGULATION
1%
2%
2%
NOTES: 1) Peak loads up to 140 Watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 140 watts.
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
RIPPLE & NOISE
%p-p (NOTE 2)
1%
1%
1%
INITIAL SETTING
ACCURACY
5.09V to 5.11V
11.97V to 12.03V
-11.4V to -12.6V
MAY 31, 2006 revised to JUL 14, 2006
Page 1 of 4