BLP30-1005G Datasheet, PDF (1/6 Pages) Power-One – 30 Watts | |||
|
BLP30 AC-DC Series Data Sheet
30 Watts
Applications
⢠Datacom (hubs, routers)
⢠POS terminals
⢠Industrial
⢠Cable modems
⢠External disk storage
⢠Medical instrumentation
⢠Computers
Features
⢠RoHS compliant for all six substances
⢠2â x 4â footprint
⢠Component height less than 1â
⢠25 W rating with natural convection cooling
⢠30 W rating with 10 CFM airflow
⢠Compliance to EMI Class B
⢠Universal AC input
⢠Short-circuit protection
⢠Overvoltage protection
⢠CE marked to Low Voltage Directive (Pending)
⢠Compliance to EN61000-4-2/-3/-4/-5/-6/-8/-11
⢠Two-year warranty
Description
The BLP30 Seriesâ economical and compact construction provides single or three-output AC to DC power
conversion to meet the requirements of most commercial and industrial applications.
Single-Output Model Selection
Model
BLP30-1005G
Nominal
Output Voltage
(VDC)
5V
BLP30-1012G
12V
BLP30-1024G
24V
Min-Max Output
Current (Amps),
Convection
0â5
0 â 2.1
0 â 1.0
Min-Max Output
Current (Amps),
Forced Air 1
0â6
0 â 2.5
0 â 1.25
Peak Output
Current
(Amps) 2
7.2
3.0
1.5
Total
Regulation
(%) 3
±2
±2
±2
Ripple &
Noise
pk-pk % 4
1
1
0.6
Triple-Output Model Selection
Model
BLP30-3000G
Nominal
Output Voltage
(VDC)
+5V
+12V
-12V
Min-Max Output
Current (Amps),
Convection
0.2 â 2.5
0.1 â 1.2
0.0 â 0.3
Min-Max Output
Current (Amps),
Forced Air 1
0.2 â 3.5
0.1 â 2.0
0.0 â 0.5
Peak Output
Current
(Amps) 2
5
3
1
Total
Regulation
(%) 3
±2
±5
±5
Ripple &
Noise
pk-pk % 4
1%
1%
1%
1 10 CFM or 260 LFM (average measurement of six equally-distributed points through a 3.5" x 1.6" (9 cm x 4 cm) cross-sectional area with
power supply mounted on a 0.25" (6.35 mm) standoffs. Recommended airflow direction is from the AC input to the DC output.
2 Peak current duration for less than 30 seconds with a max duty cycle of 10%.
3 At 25 °C ambient including voltage set point tolerance, line, and load regulation
4 Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth, measured with a twisted pair differentially
across a 10 µF E-cap and a 0.1 µF ceramic cap in parallel. The point of measurement is within 1 cm of the output connection.
JUL 05, 2006 revised to DEC 05, 2006
Page 1 of 6
www.power-one.com
|
▷ |