English
Language : 

BLP30-1005G Datasheet, PDF (1/6 Pages) Power-One – 30 Watts
BLP30 AC-DC Series Data Sheet
30 Watts
Applications
• Datacom (hubs, routers)
• POS terminals
• Industrial
• Cable modems
• External disk storage
• Medical instrumentation
• Computers
Features
• RoHS compliant for all six substances
• 2” x 4” footprint
• Component height less than 1”
• 25 W rating with natural convection cooling
• 30 W rating with 10 CFM airflow
• Compliance to EMI Class B
• Universal AC input
• Short-circuit protection
• Overvoltage protection
• CE marked to Low Voltage Directive (Pending)
• Compliance to EN61000-4-2/-3/-4/-5/-6/-8/-11
• Two-year warranty
Description
The BLP30 Series’ economical and compact construction provides single or three-output AC to DC power
conversion to meet the requirements of most commercial and industrial applications.
Single-Output Model Selection
Model
BLP30-1005G
Nominal
Output Voltage
(VDC)
5V
BLP30-1012G
12V
BLP30-1024G
24V
Min-Max Output
Current (Amps),
Convection
0–5
0 – 2.1
0 – 1.0
Min-Max Output
Current (Amps),
Forced Air 1
0–6
0 – 2.5
0 – 1.25
Peak Output
Current
(Amps) 2
7.2
3.0
1.5
Total
Regulation
(%) 3
±2
±2
±2
Ripple &
Noise
pk-pk % 4
1
1
0.6
Triple-Output Model Selection
Model
BLP30-3000G
Nominal
Output Voltage
(VDC)
+5V
+12V
-12V
Min-Max Output
Current (Amps),
Convection
0.2 – 2.5
0.1 – 1.2
0.0 – 0.3
Min-Max Output
Current (Amps),
Forced Air 1
0.2 – 3.5
0.1 – 2.0
0.0 – 0.5
Peak Output
Current
(Amps) 2
5
3
1
Total
Regulation
(%) 3
±2
±5
±5
Ripple &
Noise
pk-pk % 4
1%
1%
1%
1 10 CFM or 260 LFM (average measurement of six equally-distributed points through a 3.5" x 1.6" (9 cm x 4 cm) cross-sectional area with
power supply mounted on a 0.25" (6.35 mm) standoffs. Recommended airflow direction is from the AC input to the DC output.
2 Peak current duration for less than 30 seconds with a max duty cycle of 10%.
3 At 25 °C ambient including voltage set point tolerance, line, and load regulation
4 Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth, measured with a twisted pair differentially
across a 10 µF E-cap and a 0.1 µF ceramic cap in parallel. The point of measurement is within 1 cm of the output connection.
JUL 05, 2006 revised to DEC 05, 2006
Page 1 of 6
www.power-one.com