English
Language : 

TISP4360H3BJ Datasheet, PDF (1/16 Pages) Power Innovations Ltd – BIDIRECTIONAL THYRISTOR OVERVOLTAGE PROTECTORS
TISP4360H3BJ
BIDIRECTIONAL THYRISTOR OVERVOLTAGE PROTECTORS
Copyright © 1999, Power Innovations Limited, UK
JUNE 1999
OVERVOLTAGE PROTECTOR FOR ADSL MODEMS & SPLITTERS
q Matched to POTS + ADSL Voltages
- Working Voltage, VDRM . . . . . . . . . . . . .290 V
- Protection Voltage, V(BO). . . . . . . . . . . .360 V
SMBJ PACKAGE
(TOP VIEW)
q High FCC, Bellcore & ITU Surge Ratings
R(B) 1
2 T(A)
WAVE SHAPE
STANDARD
ITSP
A
2/10 µs
GR-1089-CORE 500
10/160 µs
FCC Part 68
250
10/700 µs
ITU-T K20/21
200
FCC Part 68
10/560 µs
FCC Part 68
160
10/1000 µs GR-1089-CORE 100
MDXXBG
device symbol
T
q High UL 1950, Bellcore & ITU AC Capability
STANDARD
UL 1950
(ANNEX NAC)
GR-1089-CORE
ITU-T K20/21
APPLIED AC
A RMS
40
7
2.2
60
30
15
2.2
23
1
‘4360 IT(OV)M LIMIT
s
0.04
4.2
SURVIVES
0.015
0.08
0.48
SURVIVES
0.15
SURVIVES
SD4XAA
R
Terminals T and R correspond to the
alternative line designators of A and B
q Large creepage distance . . . . . . . . . 2.54 mm
q Low Capacitance . . . . . . . . . . . . 24 pF @ 50 V
. . . . . . . . . . . . . .70 pF @ 0
description
The TISP4360H3BJ is designed to limit overvoltages on equipment used for telephone lines carrying POTS
(Plain Old Telephone System) and ADSL (Asymmetrical Digital Subscriber Line) signals. TISP4360H3BJ a.c.
overload limits are specified for designers to select the correct overcurrent protectors to meet safety
requirements, e.g. UL 1950.
The protector consists of a symmetrical voltage-triggered bidirectional thyristor. Overvoltages are initially
clipped by breakdown clamping. If sufficient current is available from the overvoltage, the breakdown voltage
will rise to the breakover level, which causes the device to switch into a low-voltage on-state condition. This
switching action removes the high voltage stress from the following circuitry and causes the current resulting
from the overvoltage to be safely diverted through the protector. The high holding (switch off) current prevents
d.c. latchup as the diverted current subsides.
The TISP4360H3BJ is guaranteed to voltage limit and withstand the listed international lightning surges in
both polarities. This high (H) current protection device is in a plastic SMBJ package (JEDEC DO-214AA with
J-bend leads) and supplied in embossed carrier reel pack. For alternative voltage and holding current values,
consult the factory.
PRODUCT INFORMATION
Information is current as of publication date. Products conform to specifications in accordance
with the terms of Power Innovations standard warranty. Production processing does not
necessarily include testing of all parameters.
1