English
Language : 

TISP3240F3 Datasheet, PDF (1/17 Pages) Power Innovations Ltd – DUAL SYMMETRICAL TRANSIENT VOLTAGE SUPPRESSORS
TISP3240F3, TISP3260F3, TISP3290F3, TISP3320F3, TISP3380F3
DUAL SYMMETRICAL TRANSIENT
VOLTAGE SUPPRESSORS
Copyright © 1997, Power Innovations Limited, UK
MARCH 1994 - REVISED SEPTEMBER 1997
TELECOMMUNICATION SYSTEM SECONDARY PROTECTION
q Ion-Implanted Breakdown Region
Precise and Stable Voltage
Low Voltage Overshoot under Surge
DEVICE
‘3240F3
‘3260F3
‘3290F3
‘3320F3
‘3380F3
VDRM
V
180
200
220
240
270
V(BO)
V
240
260
290
320
380
D PACKAGE
(TOP VIEW)
T1
NC 2
NC 3
R4
8G
7G
6G
5
G MDXXAE
NC - No internal connection
P PACKAGE
(TOP VIEW)
q Planar Passivated Junctions
Low Off-State Current < 10 µA
q Rated for International Surge Wave Shapes
WAVE SHAPE
STANDARD
ITSP
A
2/10 µs
FCC Part 68
175
8/20 µs
ANSI C62.41
120
10/160 µs
FCC Part 68
60
10/560 µs
FCC Part 68
45
0.5/700 µs
RLM 88
38
FTZ R12
50
10/700 µs
VDE 0433
50
CCITT IX K17/K20
50
10/1000 µs
REA PE-60
35
q Surface Mount and Through-Hole Options
T1
8T
G2
7G
G3
R4
6G
5R
MDXXAF
Specified T terminal ratings require connection of pins 1 and 8.
Specified R terminal ratings require connection of pins 4 and 5.
SL PACKAGE
(TOP VIEW)
T
1
G
2
R
3
MDXXAG MD23AA
PACKAGE
Small-outline
Small-outline taped
and reeled
Plastic DIP
Single-in-line
PART # SUFFIX
D
DR
P
SL
device symbol
T
R
q UL Recognized, E132482
description
These high voltage dual symmetrical transient
voltage suppressor devices are designed to
protect telecommunication applications with
ground backed ringing against transients caused
by lightning strikes and a.c. power lines. Offered
in five voltage variants to meet battery and
protection requirements they are guaranteed to
suppress and withstand the listed international
lightning surges in both polarities. Transients are
initially clipped by breakdown clamping until the
voltage rises to the breakover level, which
SD3XAA
G
Terminals T, R and G correspond to the
alternative line designators of A, B and C
causes the device to crowbar. The high crowbar
holding current prevents d.c. latchup as the
current subsides.
These monolithic protection devices are
fabricated in ion-implanted planar structures to
PRODUCT INFORMATION
Information is current as of publication date. Products conform to specifications in accordance
with the terms of Power Innovations standard warranty. Production processing does not
necessarily include testing of all parameters.
1