English
Language : 

PMGD-02 Datasheet, PDF (1/3 Pages) Premier Magnetics, Inc. – GATE DRIVE & BASE DRIVE TRANSFORMERS
Ê Designs for Single or Double Eneded Controllers
Ë High Isolation Voltages
Ì Designs From 20KHz to >300KHz
GATE DRIVE
& BASE DRIVE
TRANSFORMERS
Í Very Low Leakage Inductance
Î Industry Standard Packages
Ï Multiple Configurations
ELECTRICAL SPECIFICATIONS AT 25OC - OPERATING TEMPERATURE RANGE -25OC TO +80OC
CLICK ON THE RESPECTIVE PART NUMBER TO DISPLAY A DETAIL DATA SHEET
PART
NUMBER
PMGD-02
PMGD-03
PMGD-04
PMGD-05
PMGD-06
PMGD-07
PMGD-08
PMGD-09
PMGD-10
TURNS
RATIO
(Pri:Sec ± 5%)
1:1:1
1:1
1:1:1
1 : 0.67
1:1
1:2:2
1 : 1.25 : 1.25
1:2:2
1:2:2
PRIMARY
OCL
(µH Typ.)
530
800
24500
6200
6200
2350
575
2350
8350
LEAKAGE
IND
(µ H Max.)
1.5
2.0
20.0
15.0
15.0
2.0
1.0
2.0
25.0
PRI/SEC
HI-POT
V
PACKAGE
1500dc EP13
1500dc EP7
1000dc EP10
1000dc EP10
2000ac EP10
1500ac EP13
3000ac EP13
3000ac EP13
2500ac EP13
TYPICAL APPLICATION NOTE
150KHz Double Ended Drive
100KHz Single Ended Drive
20KHz Double Ended Drive
25KHz Single Ended Drive
100KHz Double Ended Drive
40KHz Dual Single Ended Drive
180KHz Dual Single Ended Drive
40KHz Dual Single Ended Drive
20KHz Dual Single Ended Drive
TYPICAL APPLICATIONS
TYPICAL SINGLE ENDED APPLICATION CIRCUIT TYPICAL DOUBLE ENDED APPLICATION CIRCUIT
+382VDC HOT RAIL >>
D
Q2
R17
G
C25
S
T1
PMGD-05
R30
D5
8
1
D7
4
5
1.5:1
3
PWM DRIVER
(ML4824)
VO2
R15
C20
R14
11
D10
Q3
D
G
S
1
D6
+Vdc
C
B Q1
E
C
B
Q1
E
DOUBLE ENDED
PWM OUTPUT
C
B
Q1
E
C
B
Q1
E
PMGD-XX
OUT A
OUT B
Specifications subject to change without notice.
pmgd 04/03
20381 BARENTS SEA CIRCLE, LAKE FOREST, CA 92630 • TEL: (949) 452-0511 • FAX: (949) 452-0512 • http://www.premiermag.com
1