English
Language : 

PLP-102 Datasheet, PDF (1/3 Pages) Premier Magnetics, Inc. – LOW PROFILE DUAL BOBBIN HIGH ISOLATION POWER TRANSFORMERS
P Premier
LOW PROFILE DUAL
M Magnetics Inc. BOBBIN HIGH ISOLATION
"INNOVATORS IN MAGNETICS TECHNOLOGY"
POWER TRANSFORMERS
! Low Height, Ideal for P.C.B. Applications
# Dual Secondaries May Be Series -OR- Parallel Connected
% Construction Minimizes Radiated Magnetic Fields
" 115/230V, 50/60Hz Dual Primaries
$ Split Bobbin Construction
& 1500Vrms Isolation (Hi-Pot)
ELECTRICAL SPECIFICATIONS AT 25OC - OPERATING TEMPERATURE RANGE -25OC TO +80OC
115/230V SIZE
PART (VA)
NUMBER
PLP-102 2.5
PLP-106 6.0
PLP-1012 12.0
PLP-122 2.5
PLP-126 6.0
PLP-1212 12.0
PLP-162 2.5
PLP-166 6.0
PLP-1612 12.0
PLP-202 2.5
PLP-206 6.0
PLP-2012 12.0
PLP-242 2.5
PLP-246 6.0
PLP-2412 12.0
PLP-302 2.5
PLP-306 6.0
PLP-3012 12.0
PLP-342 2.5
PLP-346 6.0
PLP-3412 12.0
PLP-402 2.5
PLP-406 6.0
PLP-4012 12.0
PLP-562 2.5
PLP-566 6.0
PLP-5612 12.0
PLP-882 2.5
PLP-886 6.0
PLP-8812 12.0
SECONDARY RMS RATINGS
SERIES
PARALLEL
10V C.T. @ 250mA
10V C.T. @ 600mA
10V C.T. @ 1200mA
12.6V C.T. @ 200mA
12.6V C.T. @ 450mA
12.6V C.T. @ 900mA
16V C.T. @ 150mA
16V C.T. @ 350mA
16V C.T. @ 700mA
20V C.T. @ 125mA
20V C.T. @ 300mA
20V C.T. @ 600mA
24V C.T. @ 100mA
24V C.T. @ 250mA
24V C.T. @ 500mA
30V C.T. @ 85mA
30V C.T. @ 200mA
30V C.T. @ 400mA
34V C.T. @ 75mA
34V C.T. @ 170mA
34V C.T. @ 340mA
40V C.T. @ 60mA
40V C.T. @ 150mA
40V C.T. @ 300mA
56V C.T. @ 45mA
56V C.T. @ 100mA
56V C.T. @ 200mA
88V C.T. @ 28mA
88V C.T. @ 65mA
88V C.T. @ 130mA
5V @ 500mA
5V @ 1.2A
5V @ 2.4A
6.3V @ 400mA
6.3V @ 900mA
6.3V @ 1.8A
8V @ 300mA
8V @ 700mA
8V @ 1.4A
10V @ 250mA
10V @ 600mA
10V @ 1.2A
12V @ 200mA
12V @ 500mA
12V @ 1.0A
15V @ 170mA
15V @ 400mA
15V @ 800mA
17V @ 150mA
17V @ 340mA
17V @ 680mA
20V @ 120mA
20V @ 300mA
20V @ 600mA
28V @ 90mA
28V @ 200mA
28V @ 400mA
44V @ 56mA
44V @ 130mA
44V @ 260mA
115/230V
PART
NUMBER
PLP-1024
PLP-1048
SIZE
(VA)
24.0
48.0
SECONDARY RMS RATINGS
SERIES
PARALLEL
10V C.T. @ 2.40A
10V C.T. @ 4.80A
5V @ 4.80A
5V @ 9.60A
PLP-1224 24.0 12.6V C.T. @ 1.90A
PLP-1248 48.0 12.6V C.T. @ 3.80A
6.3V @ 3.80A
6.3V @ 7.60A
PLP-1624 24.0 16V C.T. @ 1.50A
PLP-1648 48.0 16V C.T. @ 3.00A
8V @ 3.00A
8V @ 6.00A
PLP-2024 24.0 20V C.T. @ 1.20A
PLP-2048 48.0 20V C.T. @ 2.40A
10V @ 2.40A
10V @ 4.80A
PLP-2424 24.0 24V C.T. @ 1.00A
PLP-2448 48.0 24V C.T. @ 2.00A
12V @ 2.00A
12V @ 4.00A
PLP-3024 24.0 30V C.T. @ 0.80A
PLP-3048 48.0 30V C.T. @ 1.60A
15V @ 1.60A
15V @ 3.20A
PLP-3424 24.0 34V C.T. @ 0.70A
PLP-3448 48.0 34V C.T. @ 1.40A
17V @ 1.40A
17V @ 2.80A
PLP-4024 24.0 40V C.T. @ 0.60A
PLP-4048 48.0 40V C.T. @ 1.20A
20V @ 1.20A
20V @ 2.40A
PLP-5624 24.0 56V C.T. @ 0.425A
PLP-5648 48.0 56V C.T. @ 0.850A
28V @ 0.850A
28V @ 1.70A
PLP-8824 24.0 88V C.T. @ 0.270A
PLP-8848 48.0 88V C.T. @ 0.545A
44V @ 0.540A
44V @ 1.09A
SCHEMATIC
APPLICATION
1
5
PRIMARY #1
115V 50/60Hz
SEC #1
2
6
4
8
PRIMARY #2
115V 50/60Hz
SEC #2
3
7
INDICATES POLARITY
PLP-SERIES 5-SIZES:
2.5VA - 0.650" HIGH
6.0VA - 0.850" HIGH
12.0VA - 1.065" HIGH
24.0VA - 1.250" HIGH
48.0VA - 1.375" HIGH
SECONDARIES:
Connected series or parallel
PRIMARIES:
Series for 230V - 50/60Hz
Parallel for 115V - 50/60Hz
Specifications subject to change without notice.
SPLIT BOBBIN:
Provides high isolation and low
capacitive couping which minimizes
line noise.
REGULATION:
2.5VA - 30%
6.0VA - 30%
12.0VA - 20%
24.0VA - 15%
48.0VA - 15%
Note: Primary and Secondary windings are
designed to be used as one primary & one
secondary winding. That is, they must each
be used simultaneously either parallel or
series connected.
plp 4/97
20381 BARENTS SEA CIRCLE, LAKE FOREST, CA 92630 • TEL: (949) 452-0511 • FAX: (949) 452-0512 • http://www.premiermag.com
1