English
Language : 

PL611-25 Datasheet, PDF (3/5 Pages) PhaseLink Corporation – Programmable Quick Turn Clock
ELECTRICAL SPECIFICATIONS
PL611-25
Programmable Quick Turn ClockTM
ABSOLUTE MAXIMUM RATINGS
PARAMETERS
SYMBOL
MIN.
MAX.
UNITS
Supply Voltage Range
Input Voltage Range
Output Voltage Range
Data Retention @ 85º C
Soldering Temperature (Green Package)
Storage Temperature
Ambient Operating Temperature*
VDD
-0.5
4.6
V
VI
-0.5
VDD+0.5
V
VO
-0.5
VDD+0.5
V
10
Years
260
°C
TS
-65
150
°C
-40
+85
°C
Note: Exposure of the device under conditions beyond the limits specified by Maximum Ratings for extended periods may cause permanent damage to the
device and affect product reliability. These conditions represent a stress rating only, and functional operations of the device at these or any other conditions
above the operational limits noted in this specification is not implied.
* Note: Operating Temperature is guaranteed by design for all parts (COMMERCIAL and INDUSTRIAL), but tested for COMMERCIAL grade only.
AC SPECIFICATIONS
PARAMETERS
CONDITIONS
MIN.
Crystal Input Frequency
Settling Time
VDD Sensitivity
Output Rise Time
Output Fall Time
Duty Cycle
Fundamental Crystal
10
3rd Overtone Crystal
At power-up (after VDD increases over
1.62V)
Frequency vs. VDD+/-10%
-2
15pF Load, 10/90%VDD, Standard drive
15pF Load, 10/90%VDD, High drive
15pF Load, 90/10%VDD, Standard drive
15pF Load, 90/10%VDD, High drive
At VDD/2
45
Max. output skew between
same frequency clocks
Equal loading (15 pF). Equal frequency
& drive strength
Period Jitter, peak-to-peak*
(measured from 10,000
samples)
With capacitive decoupling between VDD
and GND. Operating only one output.
* Note: Jitter performance depends on the programming parameters.
47745 Fremont Blvd., Fremont, California 94538 Tel (510) 492-0990 Fax (510) 492-0991
TYP.
2.5
1.0
2.5
1.0
50
40
MAX.
30
75
UNITS
MHz
MHz
10
ms
2
ppm
3.5
ns
1.5
ns
3.5
ns
1.5
ns
55
%
500
ps
ps
Rev 10/05/05 Page 3