English
Language : 

1415197 Datasheet, PDF (3/5 Pages) PHOENIX CONTACT – Power cable - SAC-4P-MRT/ 2,0-PUR/FRT SCO
https://www.phoenixcontact.com/us/products/1415197
Power cable - SAC-4P-MRT/ 2,0-PUR/FRT SCO - 1415197
Technical data
Cable
Minimum bending radius, fixed installation
Minimum bending radius, flexible installation
Number of bending cycles
Minimum bending radius, drag chain applications
Traversing path
Traversing rate
Acceleration
Cable weight
Outer sheath, material
Material conductor insulation
Conductor material
Insulation resistance
Conductor resistance
Nominal voltage, cable
Test voltage, cable
Flame resistance
Halogen-free
Resistance to oil
Other resistance
Ambient temperature (operation)
5xD
10 x D
4000000
10 x D
10 m
3 m/s
10 m/s²
109 kg/km
PUR
PP
Bare Cu litz wires
≥ 1 GΩ*km (at 20 °C)
≤ 13 Ω/km (at 20 °C)
≤ 300 V AC
≥ 3000 V AC (Spark test)
According to UL 758/1581 (Cable Flame)
According to UL 758/1581 FT1
According to DIN EN 60332-1-2
in accordance with DIN VDE 0472 part 815
in accordance with DIN EN 50267-2-1
According to DIN EN 60811-2-1, 168 h at 100°C
According to UL 758, 168 h at 60°C
Hydrolysis and microbe resistant as per VDE 0282 section 10
Low adhesion
abrasion-resistant
Resistant to salt water
-50 °C ... 80 °C (cable, fixed installation)
-30 °C ... 80 °C (cable, flexible installation)
Drawings
Schematic diagram
Schematic diagram
4
3
12
4
1
3
2
Pin assignment for M12 plug, 4-pos., T-coded, view of plug side
Pin assignment of M12 socket, 4-pos., T-coded, socket side view
08/11/2016 Page 3 / 5