Technical data
Cable
Material conductor insulation
Conductor material
Insulation resistance
Conductor resistance
Nominal voltage, cable
Test voltage, cable
Special properties
Flame resistance
Resistance to oil
Other resistance
Ambient temperature (operation)
PVC
Bare Cu litz wires
≥ 200 MΩ*km (at 20 °C)
78 Ω/km (at 20 °C)
≤ 300 V AC
≥ 3000 V AC (Spark test)
Flexible use, however not recommended for use in drag chains
Low adhesion surface
wear-resistant and notch tough
according to UL 758/1581 (horizontal)
in accordance with UL 758/1581 FT2
According to DIN EN 60811-2-1, 168 h at 100°C
hydrolysis and microbe resistant
Resistant to salt water
-40 °C ... 80 °C (cable, fixed installation)
-20 °C ... 80 °C (cable, flexible installation)
Drawings
Dimensional drawing
Circuit diagram
Ø14,8
M12
34,5
1
WH
2
GN
3
YE
4
GY
5
BN
6
7
BU
8
M12 x 1 socket, angled
Classifications
eCl@ss
eCl@ss 4.0
eCl@ss 4.1
eCl@ss 5.0
eCl@ss 5.1
272607xx
27260701
27260701
27061801
08/02/2016 Page 3 / 4