Table 7. Dynamic characteristics …continued
Voltages are referenced to GND (ground = 0 V); CL = 50 pF unless otherwise specified; for test circuit see Figure 8.
Symbol Parameter Conditions
25 C
Tamb
Unit
40 C to +85 C 40 C to +125 C
Min Typ Max Min Max
Min
Max
CPD
power
CL = 50 pF; f = 1 MHz;
[3] -
44 -
-
-
-
-
pF
dissipation VI = GND to VCC  1.5 V
capacitance
[1] tpd is the same as tPLH and tPHL.
[2] tt is the same as tTHL and tTLH.
[3] CPD is used to determine the dynamic power dissipation (PD in W).
PD = CPD  VCC2  fi  N + (CL  VCC2  fo) where:
fi = input frequency in MHz;
fo = output frequency in MHz;
CL = output load capacitance in pF;
VCC = supply voltage in V;
N = number of inputs switching;
(CL  VCC2  fo) = sum of outputs.
11. Waveforms
Q$Q
LQSXW
9&&
*1'
Q<Q
LQSXW
92+
92/
90
W3+/
90
W7+/
W3/+
W7/+
DDD
Fig 6.
Measurement points are given in Table 8.
VOL and VOH are typical voltage output levels that occur with the output load.
Propagation delay input (nAn) to output (nYn) and transition time output (nYn)
74HC_HCT139
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 3 — 28 March 2014
© NXP Semiconductors N.V. 2014. All rights reserved.
8 of 18