KMZ10A1 Datasheet, PDF (5/12 Pages) NXP Semiconductors – Magnetic field sensor | |||
|
◁ |
Philips Semiconductors
Magnetic ï¬eld sensor
Product speciï¬cation
KMZ10A1
12
handbook, halfpage
,,,,, Hd
(kA/m)
Hy
,,,,, 8
Hx Hd
MGD807
II
,,,,,,,,,, 4
,,,,,,,,,, II
0
,,,,, 0
1
SOAR
I
2
3
4
Hx (kA/m)
I = Region of permissible operation.
II = Permissible extension if Hy < 0.05 kA/m.
In applications with Hx < 3 kA/m, the sensor has to be reset, after
leaving the SOAR, by an auxiliary field of Hx = 3 kA/m.
Fig.4 Safe Operating Area (permissible disturbing
field Hd as a component of auxiliary field Hx).
1.2
handbook, halfpage
S(H x )
S(0.5 kA/m)
0.8
MLC120
0.4
0
0
1
2
3
4
5
H x (kA/m)
In applications with Hx ⤠3 kA/m, the sensor has to be
reset by an auxiliary field of Hx = 3 kA/m before use.
Fig.5 Relative sensitivity (ratio of sensitivity at
certain Hx and sensitivity at Hx = 0.5 kA/m).
handboo1k0, halfpage
VO
(mV/V)
6
2
0
â2
MEA558
â Hy
â VO
â6
â10
â0.5
â0.3
â0.1 0 0.1
0.3
0.5
Hy (kA/m)
Hx = 0.5 kA/m; Tamb = 25 °C; Voffset = 0; S = âVO / âHy.
Fig.6 Sensor output characteristics.
handbVooOk1, .h2alfpage
(mV/V)
0.8
0.4
MEA557
(1)
0
(2)
â0.4
â0.8
â1.2
â50
â30
â10 0 10
30
50
Hy (A/m)
(1) Sensor reset with Hx = 3 kA/m.
(2) Sensor reset with Hx = â3 kA/m.
Fig.7 Output characteristic with Hx = 0
(switched Hx).
1998 Apr 06
5
|
▷ |