English
Language : 

SA5775A Datasheet, PDF (4/10 Pages) NXP Semiconductors – Differential air core meter driver
Philips Semiconductors
Differential air-core meter driver
Product specification
SA5775A
Table 2. SA5775A Pin Descriptions for the D Package (Small Outline)
Pin # Name
Function
1.
SIN– Negative output connection to the SIN coil of the gauge.
2.
SIN+ Positive output connection to the SIN coil of the gauge.
3.
NC No connect
4.
NC No connect
5.
NC No connect
6.
AGND Ground for VIGN supply. Pins 6, 20 and 23 connected on the circuit board.
7.
VIGN Analog supply. Nominally 14.0V.
8.
DATAOUT
Serial data output. Output of the internal shift register. When a new data word is shifted in, the old word is shifted out the
DATAOUT pin.
9. DATAIN Serial data input. A new data word is serially shifted into the part on the rising edge of SCLK. The data is shifted in MSB first.
10.
NC No connect
11.
NC No connect
12.
NC No connect
13.
VCC 5 V logic supply. The internal latches and registers are set to zero on the rising edge of this signal.
14.
OE Output drivers are turned off when this input is low. Current draw is minimized.
15. SCLK Serial clock input. Data is loaded into the part on the rising edge of SCLK.
16.
CS
Active high chip select input. When CS is high, the part is enabled to receive a new serial input word. The high-to-low
transition of CS loads the new 10-bit word into the DAC registers and updates the output.
17.
NC No connect
18.
NC No connect
Status output from this IC to indicate that the outputs have been disabled. The outputs may be disabled due to shorted out-
19.
ST puts, over temperature conditions, power up reset, or output enable control pin. This output is an open drain output. Multiple
status outputs may be wire OR’ed together. This output is low when the outputs are disabled due to a fault condition.
20. DGND Ground for VCC supply. Connect to Pins 6 and 23.
21.
NC No connect
22.
NC No connect
23. AGND Ground for VBB supply. Connect to Pins 6 and 20.
24.
NC No connect
25.
NC No connect
26.
NC No connect
27. COS– Negative output connection to the COS coil of the gauge.
28. COS+ Positive output connection to the COS coil of the gauge.
ABSOLUTE MAXIMUM RATINGS
SYMBOL
PARAMETER
VIGN
VCC
DGND to AGND
VIN
PD
Analog supply
Digital supply
Ground difference
Digital input voltage, Data In, OE, CS, SCLK
Power dissipation (TA = 25°C)1
D and N packages
TA
Ambient operating temperature
TJ
Junction temperature
θJA
DIP and SO packages
NOTE:
1. For power dissipation ratings in still air, derate above 25°C at the following rates:
D and N packages at 12mW/°C
RATING
-1 to +23
-1 to +6
-0.3 to +0.3
-1 to +7
1500
–40 to +85
150
90
UNIT
V
V
V
V
mW
°C
°C
°C/W
1999 Sep 20