BGY681 Datasheet, PDF (4/5 Pages) NXP Semiconductors – CATV amplifier module | |||
|
◁ |
Philips Semiconductors
CATV ampliï¬er module
Product speciï¬cation
BGY681
CHARACTERISTICS
Bandwidth 40 to 550 MHz; VB = 24 V; Tmb = 30 °C; ZS = ZL = 75 â¦.
SYMBOL
Gp
SL
FL
S11
S22
S21
CTB
Xmod
CSO
d2
Vo
F
Itot
PARAMETER
power gain
slope cable equivalent
ï¬atness of frequency response
input return losses
output return losses
phase response
composite triple beat
cross modulation
composite second order distortion
second order distortion
output voltage
noise ï¬gure
total current consumption (DC)
CONDITIONS
f = 50 MHz
f = 550 MHz
f = 40 to 550 MHz
f = 40 to 550 MHz
f = 40 to 80 MHz
f = 80 to 160 MHz
f = 160 to 550 MHz
f = 40 to 80 MHz
f = 80 to 160 MHz
f = 160 to 550 MHz
f = 50 MHz
77 channels ï¬at;
Vo = 44 dBmV;
measured at 547.25 MHz
77 channels ï¬at;
Vo = 44 dBmV;
measured at 55.25 MHz
77 channels ï¬at;
Vo = 44 dBmV;
measured at 548.5 MHz
note 1
dim = â60 dB; note 2
f = 550 MHz
note 3
MIN.
12
12.5
0.5
â
20
19
18
20
19
18
â45
â
TYP.
â
â
â
â
â
â
â
â
â
â
â
â
MAX. UNIT
13
dB
14.5 dB
2
dB
±0.2 dB
â
dB
â
dB
â
dB
â
dB
â
dB
â
dB
+45 deg
â56 dB
â
â
â62 dB
â
â
â59 dB
â
â
â72 dB
61.5 â
â
dBmV
â
â
9
dB
â
220 240 mA
Notes
1. fp = 55.25 MHz; Vp = 44 dBmV;
fq = 493.25 MHz; Vq = 44 dBmV;
measured at fp + fq = 548.5 MHz.
2. Measured according to DIN45004B:
fp = 540.25 MHz; Vp = Vo;
fq = 547.25 MHz; Vq = Vo â6 dB;
fr = 549.25 MHz; Vr = Vo â6 dB;
measured at fp + fq â fr = 538.25 MHz.
3. The module normally operates at VB = 24 V, but is able to withstand supply transients up to 30 V.
February 1995
4
|
▷ |