ABSOLUTE MAXIMUM RATINGS
(Operation beyond the limits set forth in this table may impair the useful life of the device.
Unless otherwise noted these limits are over the operating free-air temperature range.)
SYMBOL
PARAMETER
VCC
VIN
IIN
VOUT
IOUT
Supply voltage
Input voltage
Input current
Voltage applied to output in High output state
Current applied to output in Low output state
A0–A7
B0–B7
Tamb
Tstg
Operating free-air temperature range
Storage temperature range
RATING
–0.5 to +7.0
–0.5 to +7.0
–30 to +5
–0.5 to +5.5
48
128
0 to +70
–65 to +150
UNIT
V
V
mA
V
mA
mA
°C
°C
RECOMMENDED OPERATING CONDITIONS
SYMBOL
PARAMETER
VCC
VIH
VIL
IIK
VOH
IOL
Tamb
Supply voltage
High-level input voltage
Low-level input voltage
Input clamp current
High-level output current
Low-level output current
Operating free-air temperature range
A0–A7
B0–B7
LIMITS
MIN
NOM
MAX
4.5
5.0
5.5
2.0
0.8
–18
4.5
24
64
0
70
UNIT
V
V
V
mA
V
mA
mA
°C
DC ELECTRICAL CHARACTERISTICS
(Over recommended operating free-air temperature range unless otherwise noted.)
SYMBOL
PARAMETER
TEST CONDITIONSNO TAG
LIMITS
MIN
TYP
NO TAG
MAX
UNIT
IOH
High-level output current
VCC = MIN, VIL = MAX, VIH=MIN, VOH = MAX
250
µA
±10%VCC
VOL
Low-level output
voltage
A0–A7
B0–B7
VCC = MIN,
VIL = MAX,
VIH = MIN,
IOL = 24mA
IOL = 48mA
±5%VCC
±10%VCC
IOL = 64mA
±5%VCC
0.35 0.50
V
0.35 0.50
V
0.38 0.55
V
0.42 0.55
V
VIK
Input clamp voltage
VCC = MIN, II = IIK
–0.73 –1.2
V
Input current at
OEBA, OEAB VCC = MAX, VI = 7.0V
II
maximum input
voltage
others
VCC = 0.0V, VI = 5.5V
100
µA
1
mA
IIH
High-level input current
VCC = MAX, VI = 2.7V
20
µA
IIL
Low-level input current
VCC = MAX, VI = 0.5V
–20
µA
ICC
Supply current
(total)
ICCH
ICCL
VCC = MAX
OEBA = OEAB = A0–A7 = 4.5V
OEBA = OEAB = 4.5V,
A0–A7 = GND
105
140
mA
105
140
mA
NOTES:
1. For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions for the applicable type.
2. All typical values are at VCC = 5V, Tamb = 25°C.
1996 Jan 05
4