English
Language : 

TDA3681 Datasheet, PDF (17/28 Pages) NXP Semiconductors – Multiple voltage regulator with switch and ignition buffer
Philips Semiconductors
Multiple voltage regulator with switch and
ignition buffer
Product specification
TDA3681
SYMBOL
VIL(clamp)
PARAMETER
LOW-level input
clamping voltage
CONDITIONS
MIN.
TYP.
−0.6 −
MAX.
0
UNIT
V
Ignition buffer
VOL
LOW-level output voltage IIGNOUT = 0 mA
0
0.2
0.8
V
VOH
HIGH-level output
IIGNOUT = 0 mA
voltage
4.5 5.0
5.25
V
IOL
LOW-level output current VIGNOUT ≤ 0.8 V
IOH
HIGH-level output
VIGNOUT ≥ 4.5 V
current
0.45 0.8
−
mA
−0.45 −2.0
−
mA
ILO
output leakage current VIGNOUT = 5 V; VIGNIN = 0 V −
−
(source)
1.0
µA
tPLH
LOW-to-HIGH
VIGNIN rising from 1.7 to 2.5 V −
−
propagation time
500
µs
tPHL
HIGH-to-LOW
VIGNIN falling from 2.5 to 1.7 V −
−
propagation time
500
µs
Temperature protection
Tj(sd)
junction temperature for
shutdown
Tj(hold)
junction temperature for
hold trigger
150 160
170
°C
150 160
170
°C
Notes
1. Minimum operating voltage, only if VP1 has exceeded 6.5 V.
2. The total quiescent current is measured in the standby mode. Therefore, the enable inputs of regulators 1, 3, 4 and
the power switch are grounded and RL(REG2) = ∞ ; see Figs 10 and 11.
3. The voltage of the regulator drops as a result of a VP1 drop for regulators 1 and 2. Regulators 3 and 4 drop as a result
of VP2 drop.
4. The rise and fall times are measured with a 10 kΩ pull-up resistor and a 50 pF load capacitor.
5. The delay time depends on the value of the reset delay capacitor: td(RES) = I--Cc---h- × VC(th) = C × (750 × 103)[s]
6. The delay time depends on the value of the reset delay capacitor: td(SW) = I--Cc---h- × VC(th) = C × (375 × 103)[s]
7. The drop-out voltage of regulators 1 and 2 is measured between pins VP1 and REGn. The drop-out voltage of
regulators 3 and 4 is measured between pins VP2 and REGn.
8. At current limit, Im(REGn) is held constant (see Fig.8).
9. The foldback current protection limits the dissipated power at short-circuit (see Fig.8).
10. The drop-out voltage is measured between pins BU and REG2.
11. The drop-out voltage of the power switch is measured between pins VP1 and SW.
12. The maximum output current of the power switch is limited to 1.8 A when the supply voltage exceeds 18 V.
13. At short-circuit, Isc(SW) of the power switch is held constant to a lower value than the continuous current after a delay
of at least 10 ms.
2002 Apr 10
17