English
Language : 

SAA4993H Datasheet, PDF (14/40 Pages) NXP Semiconductors – Field and line rate converter with noise reduction
This text is here in white to force landscape pages to be rotated correctly when browsing through the pdf in the Acrobat reader.This text is here in
_white to force landscape pages to be rotated correctly when browsing through the pdf in the Acrobat reader.This text is here inThis text is here in
white to force landscape pages to be rotated correctly when browsing through the pdf in the Acrobat reader. white to force landscape pages to be ...
8 CONTROL REGISTER DESCRIPTION
NAME
DNR/peaking/colour
Kstep10
Kstep0
Kstep1
Kstep32
Kstep2
Kstep3
Kstep54
Kstep4
Kstep5
Kstep76
Kstep6
Kstep7
Gain_fix_y
FixvalY
GainY
FixY
Gain_fix_uv
FixvalUV
GainUV
FixUV
Peak_Vcomp
VecComp
PeakCoef
SNERT
ADDRESS
(HEX)
READ/
WRITE(1)
7
6
5
4
3
2
1
0
DESCRIPTION(2)
010
write; S
X X X X set LUT value: k = 1⁄16 if difference below (0 to 15)
XXXX
set LUT value: k = 1⁄8 if difference below (0 to 15)
011
write; S
X X X X set LUT value: k = 2⁄8 if difference below (0 to 30 in multiples of 2)
XXXX
set LUT value: k = 3⁄8 if difference below (0 to 30 in multiples of 2)
012
write; S
X X X X set LUT value: k = 4⁄8 if difference below (0 to 60 in multiples of 4)
XXXX
set LUT value: k = 5⁄8 if difference below (0 to 60 in multiples of 4)
013
write; S
X X X X set LUT value: k = 6⁄8 if difference below (0, 8, 16, 24, 32, 40, 48, 56,
64, 72, 80, 88, 96, 104, 112 or 120)
XXXX
set LUT value: k = 7⁄8 if difference below (0, 8, 16, 24, 32, 40, 48, 56,
64, 72, 80, 88, 96, 104, 112 or 120)
014
write; S
X X X X set fixed Y value; used when FixY = 1 or in left part of split screen
(0, 1⁄16 to 14⁄16 or 16⁄16)
XXX
set gain in difference signal for adaptive DNR Y (1⁄8, 1⁄4, 1⁄2, 1, 2 or 4)
X
select fixed Y (adaptive or fixed) (full screen)
015
write; S
X X X X set fixed UV value; used when FixUV = 1 or in left part of split screen
(0, 1⁄16 to 14⁄16 or 16⁄16)
XXX
set gain in difference signal for adaptive DNR UV (1⁄8, 1⁄4, 1⁄2, 1, 2 or 4)
X
select fixed UV (adaptive or fixed) (full screen)
016
write; S
XXXX
X X X set degree of horizontal vector compensation in Y DNR:
(0, 1⁄8, 2⁄8, 3⁄8, 4⁄8, 5⁄8, 6⁄8 or 7⁄8) of the vector
set vertical peaking level: (0, +2, +3.5, +5, +6, x, x, x, x, x, x, x, x,
−12, −6 or −2.5) dB